Publication: Analoque and digital analysis of the effects of some parameters in determination of the best experimental energy resolution
dc.contributor.author | Ermiş, Elif Ebru | |
dc.contributor.author | Tektaş, Gözde | |
dc.contributor.author | Piliçer, Ercan | |
dc.contributor.author | Çeliktaş, Cüneyt | |
dc.contributor.author | Pechousek, Jiri | |
dc.contributor.buuauthor | Piliçer, Ercan | |
dc.contributor.department | Fen Edebiyat Fakültesi | |
dc.contributor.department | Fizik Bölümü | |
dc.contributor.researcherid | JKM-6730-2023 | |
dc.date.accessioned | 2024-10-15T05:21:11Z | |
dc.date.available | 2024-10-15T05:21:11Z | |
dc.date.issued | 2014-01-01 | |
dc.description.abstract | The gamma-ray energy spectrum of Cs-137 was obtained according to different parameters such as preamplifier capacitance, the amplifier's coarse gain level, power supply voltage for the detector, and source-to-detector distance. This investigation was performed with both analogue and digital methods. In order to examine the effects of these parameters on energy resolution, a NaI(Tl) inorganic scintillation detector was used. In addition, the gamma energy spectrum of the radioisotope was obtained by means of FLUKA, which is one of the Monte Carlo simulation programmes. Energy resolution of the detector by these 3 methods was calculated. These resolution values were compared with each other. Effects of the parameters above on the resolutions from analogue and digital methods were discussed. | |
dc.description.sponsorship | Centre of Science and Technology of Ege University (EBILTEM) - 99 BIL 001 | |
dc.description.sponsorship | Operational Programme 'Research and Development for Innovations' of the European Regional Development Fund CZ.1.05/2.1.00/03.0058 | |
dc.description.sponsorship | Operational Programme 'Education for Competitiveness' of the European Social Fund CZ.1.07/2.3.00/20.0155 | |
dc.description.sponsorship | Ministry of Education, Youth & Sports - Czech Republic | |
dc.identifier.doi | 10.3906/fiz-1401-10 | |
dc.identifier.endpage | 213 | |
dc.identifier.issn | 1300-0101 | |
dc.identifier.issue | 2 | |
dc.identifier.scopus | 2-s2.0-84905979399 | |
dc.identifier.startpage | 203 | |
dc.identifier.uri | https://doi.org/10.3906/fiz-1401-10 | |
dc.identifier.uri | https://journals.tubitak.gov.tr/physics/vol38/iss2/6/ | |
dc.identifier.uri | https://hdl.handle.net/11452/46408 | |
dc.identifier.volume | 38 | |
dc.identifier.wos | 000420334600006 | |
dc.indexed.wos | WOS.ESCI | |
dc.language.iso | en | |
dc.publisher | TÜBİTAK | |
dc.relation.journal | Turkish Journal of Physics | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
dc.relation.tubitak | 197T087 | |
dc.relation.tubitak | 111T571 | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Gamma-ray | |
dc.subject | Analogue and digital data acquisition | |
dc.subject | Nai(tl) inorganic scintillation detector | |
dc.subject | Fluka mc simulation method | |
dc.subject | Physics | |
dc.title | Analoque and digital analysis of the effects of some parameters in determination of the best experimental energy resolution | |
dc.type | Article | |
dspace.entity.type | Publication | |
local.contributor.department | Fen Edebiyat Fakültesi/Fizik Bölümü | |
local.indexed.at | WOS | |
local.indexed.at | Scopus |
Files
Original bundle
1 - 1 of 1