Publication:
Analoque and digital analysis of the effects of some parameters in determination of the best experimental energy resolution

dc.contributor.authorErmiş, Elif Ebru
dc.contributor.authorTektaş, Gözde
dc.contributor.authorPiliçer, Ercan
dc.contributor.authorÇeliktaş, Cüneyt
dc.contributor.authorPechousek, Jiri
dc.contributor.buuauthorPiliçer, Ercan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Bölümü
dc.contributor.researcheridJKM-6730-2023
dc.date.accessioned2024-10-15T05:21:11Z
dc.date.available2024-10-15T05:21:11Z
dc.date.issued2014-01-01
dc.description.abstractThe gamma-ray energy spectrum of Cs-137 was obtained according to different parameters such as preamplifier capacitance, the amplifier's coarse gain level, power supply voltage for the detector, and source-to-detector distance. This investigation was performed with both analogue and digital methods. In order to examine the effects of these parameters on energy resolution, a NaI(Tl) inorganic scintillation detector was used. In addition, the gamma energy spectrum of the radioisotope was obtained by means of FLUKA, which is one of the Monte Carlo simulation programmes. Energy resolution of the detector by these 3 methods was calculated. These resolution values were compared with each other. Effects of the parameters above on the resolutions from analogue and digital methods were discussed.
dc.description.sponsorshipCentre of Science and Technology of Ege University (EBILTEM) - 99 BIL 001
dc.description.sponsorshipOperational Programme 'Research and Development for Innovations' of the European Regional Development Fund CZ.1.05/2.1.00/03.0058
dc.description.sponsorshipOperational Programme 'Education for Competitiveness' of the European Social Fund CZ.1.07/2.3.00/20.0155
dc.description.sponsorshipMinistry of Education, Youth & Sports - Czech Republic
dc.identifier.doi10.3906/fiz-1401-10
dc.identifier.endpage213
dc.identifier.issn1300-0101
dc.identifier.issue2
dc.identifier.scopus2-s2.0-84905979399
dc.identifier.startpage203
dc.identifier.urihttps://doi.org/10.3906/fiz-1401-10
dc.identifier.urihttps://journals.tubitak.gov.tr/physics/vol38/iss2/6/
dc.identifier.urihttps://hdl.handle.net/11452/46408
dc.identifier.volume38
dc.identifier.wos000420334600006
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherTÜBİTAK
dc.relation.journalTurkish Journal of Physics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.relation.tubitak197T087
dc.relation.tubitak111T571
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGamma-ray
dc.subjectAnalogue and digital data acquisition
dc.subjectNai(tl) inorganic scintillation detector
dc.subjectFluka mc simulation method
dc.subjectPhysics
dc.titleAnaloque and digital analysis of the effects of some parameters in determination of the best experimental energy resolution
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atWOS
local.indexed.atScopus

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Pilicer_vd_2014.pdf
Size:
529.7 KB
Format:
Adobe Portable Document Format