Publication:
The effect of the design of a mandibular implant-supported zirconia prosthesis on stress distribution

dc.contributor.authorOyar, Perihan
dc.contributor.authorDurkan, Rükiye
dc.contributor.authorDeste, Gonca Gökay
dc.contributor.buuauthorDESTE GÖKAY, GONCA
dc.contributor.departmentBursa Uludağ Üniversitesi/Diş Hekimliği Fakültesi/Protetik Diş Tedavisi Anabilim Dalı
dc.contributor.orcid0000-0002-5481-0063
dc.contributor.researcheridAAM-7219-2020
dc.date.accessioned2024-06-07T11:50:05Z
dc.date.available2024-06-07T11:50:05Z
dc.date.issued2021-03-04
dc.description.abstractStatement of problem. Prosthetic complications have been frequently reported in implant supported complete-arch prosthesis. Prosthetic restorations designed with an all-on-four treatment concept and fabricated from zirconia ceramic may be used to overcome these problems.Purpose. The purpose of this biomechanical study was to evaluate the effects of cantilever length and inclination of implant on the stress distribution in bone tissue, implant, and a monolithic zirconia ceramic-lithium disilicate glass-ceramic superstructure for all-on-four prosthesis.Material and methods. All-on-four mandibular prosthesis fabricated from a zirconia and lithium disilicate glass-ceramic (LDGC) superstructure was designed with cantilever lengths of either 5 mm or 9 mm and posterior implants with a distal tilt of either 15 or 30 degrees. Stresses were evaluated with a simulated application of a static load of 600 N.Results. Increasing implant inclination from 15 to 30 degrees led to a decrease in maximum principal stress (MaxPS) values of approximately 4 to 7 MPa in cortical bone around all implants except the right anterior implant in the designs with short cantilevers and an increase in MaxPS values (approximately 3 to 19 MPa) in the same places in the designs with the long cantilevers. Increasing cantilever length from 5 to 9 mm resulted in an increase in minimum principal stress (MinPS) values of approximately 3 to 13 MPa in the cortical bone surrounding all posterior implants. In the designs with the long cantilever, MaxPS values increased approximately 3 to 4 MPa in spongy bone adjacent to the right posterior implant. An increase in cantilever length also led to higher vMS values at the first and second implant grooves in the right posterior implant in the design with the 15-degree implant tilt. An increase in implant inclination in the design with the short cantilever resulted in lower vMS values at the apex and all grooves of the left posterior implant, whereas in the design with the long cantilever, an increase in implant inclination resulted in lower stress values in the first and second grooves of the same implant. An increase in implant inclination led to in an increase in vMS values in the core structure.Conclusions. In zirconia ceramic restorations by using an all-on-four design with an LDGC superstructure, short cantilevers may be preferable because they result in a more favorable distribution of stress than long cantilevers. An increase in implant angulation from 15 to 30 degrees decreased MaxPS values in cortical bone.
dc.identifier.doi10.1016/j.prosdent.2020.05.027
dc.identifier.eissn1097-6841
dc.identifier.issn0022-3913
dc.identifier.issue3
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2020.05.027
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0022391320304273
dc.identifier.urihttps://hdl.handle.net/11452/41887
dc.identifier.volume125
dc.identifier.wos000631751100005
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherElsevier
dc.relation.journalJournal of Prosthetic Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectFinite-element-analysis
dc.subjectDenture-bearing area
dc.subjectImmediate function
dc.subjectOverdenture attachment
dc.subjectLithium-disilicate
dc.subjectDentistry
dc.subjectSelection
dc.subjectLength
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectDentistry, oral surgery & medicine
dc.titleThe effect of the design of a mandibular implant-supported zirconia prosthesis on stress distribution
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication445cb9ac-17e5-4716-8945-a46301346983
relation.isAuthorOfPublication.latestForDiscovery445cb9ac-17e5-4716-8945-a46301346983

Files

Collections