Yayın:
Comparison of the effects of laser systems and cold atmospheric plasma on the surface roughness and shear bond strength of flexible hybrid ceramics

dc.contributor.authorAladağ, Seda Üstün
dc.contributor.authorAyaz, Elif Aydoğan
dc.contributor.buuauthorÜSTÜN ALADAĞ, SEDA
dc.contributor.departmentDiş Hekimliği Fakültesi
dc.contributor.departmentProtetik Diş Tedavisi Ana Bilim Dalı
dc.contributor.orcid0000-0002-6990-4660
dc.contributor.researcheridAAK-7239-2021
dc.date.accessioned2025-02-11T11:31:39Z
dc.date.available2025-02-11T11:31:39Z
dc.date.issued2024-11-13
dc.description.abstractThe aim of this study was to compare the effects of laser systems and cold atmospheric plasma (CAP) on the surface roughness (Ra) and shear bond strength (SBS) of flexible hybrid ceramics (FHCs). Eighty FHC samples were divided into 5 groups to be subjected to surface treatments (hydrofluoric acid (HFA), HFA + 5 W Er: YAG laser (HFA + 5WE), HFA + 3 W Er: YAG laser (HFA + 3WE), HFA + ultrafast fiber laser (HFA + FL), and CAP). The Er: YAG laser (AT Fidelis Plus III, Fotona, Slovenia) was operated with a 0.9 mm diameter tip, delivering 250 mJ and 150 mJ per pulse, with output powers of 5 W and 3 W, and fluences of 23,623 J/cm(2) and 14,157 J/cm(2), respectively, at a frequency of 20 Hz and a pulse duration of 600 mu s for 30 s. The FL (FiberLAST Inc., Turkey) was applied with a 7 mm spot size, 1 mJ pulse energy, 20 W output power, 100 kHz repetition rate, ultrashort pulse length (100 ns), and the fluence of 1,820 J/cm(2) for 7 s. The CAP (PiezoBrush PZ3, Relyon Plasma, Germany) applied to the surfaces for 80 s at a treatment speed of 5 cm2/s and 100% plasma power. After the Ra values were measured, each group was divided into 2 subgroups to be cemented with total-etch (TE) and self-adhesive (SA) resin cements. The SBS of all the samples was measured. One sample was randomly selected from each group, and the fractured surfaces were examined by SEM analysis. The significance level was at P < 0.05. HFA + FL had the highest Ra values, and there was no significant difference between HFA + FL and HFA + 5WE (P > 0.05). There was no difference in Ra between CAP and HFA (P > 0.05). The highest SBS values were observed for the samples cemented with TE after HFA + FL. The difference between the SBS values of the groups cemented with TE after CAP, HFA + 5WE, HFA + 3WE, and HFA + FL was not significant (P < 0.05). The use of FL may be a promising method to improve SBS without causing thermal damage when using TE or SA cements. CAP can be recommended as a practical and safe treatment with SA cement because it is suitable for chairside use with a handheld device and does not change the physical properties of the material.
dc.identifier.doi10.1007/s10103-024-04238-1
dc.identifier.eissn1435-604X
dc.identifier.issn0268-8921
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85209175489
dc.identifier.urihttps://doi.org/10.1007/s10103-024-04238-1
dc.identifier.urihttps://link.springer.com/article/10.1007/s10103-024-04238-1
dc.identifier.urihttps://hdl.handle.net/11452/50275
dc.identifier.volume39
dc.identifier.wos001354436200001
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherSpringer
dc.relation.journalLasers in Medical Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSelf-adhesive
dc.subjectEryag laser
dc.subjectResin
dc.subjectComposite
dc.subjectBlocks
dc.subjectCement
dc.subjectAcid
dc.subjectCad-cam materials
dc.subjectCold atmospheric plasma
dc.subjectEr:yag laser
dc.subjectUltrafast fiber laser
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectLife sciences & biomedicine
dc.subjectEngineering, biomedical
dc.subjectSurgery
dc.subjectEngineering
dc.titleComparison of the effects of laser systems and cold atmospheric plasma on the surface roughness and shear bond strength of flexible hybrid ceramics
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentDiş Hekimliği Fakültesi/Protetik Diş Tedavisi Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus
relation.isAuthorOfPublicationc4c0b654-1860-46c6-89ff-c5db1166ced9
relation.isAuthorOfPublication.latestForDiscoveryc4c0b654-1860-46c6-89ff-c5db1166ced9

Dosyalar