Yayın: Evaluation of biomechanical effects of prosthetic components with different materials on the abutment screw
| dc.contributor.author | Gökay, Gonca Deste | |
| dc.contributor.author | Gökçimen, Gülsüm | |
| dc.contributor.author | Durkan, Rukiye | |
| dc.contributor.buuauthor | DESTE GÖKAY, GONCA | |
| dc.contributor.department | Diş Hekimliği Fakültesi | |
| dc.contributor.department | Protetik Diş Tedavisi Ana Bilim Dalı | |
| dc.contributor.scopusid | 57222483984 | |
| dc.date.accessioned | 2025-05-13T06:55:47Z | |
| dc.date.issued | 2021-01-01 | |
| dc.description.abstract | Objectives: The aim of this study was to assess the effects of different resin-based and ceramic superstructure materials and two different abutment types on the stress distribution of the abutment screw using the method of three-dimensional finite element stress analysis. Materials and Methods: A three-dimensional implant, abutment (zirconia and titanium), abutment screw, crown (zirconia reinforced lithium silicate, lithium disilicate, polymer-infiltrated resin ceramic, and PEEK), and alveolar bone were designed using Rhinoceros 3D modeling software and VRMesh Studio software to form 8 simulations. On the models prepared, loading was made on the lingual tubercle of the maxillary right first premolar crown at an angle of 30° with 150 N force obliquely in the buccolingual direction. The von Mises stress values obtained from the abutment screw were compared according to the types of abutment and crown materials. Results: The von Mises stress values in the abutment screw were higher in the models using a titanium abutment (on average 1336.24 MPa), and the lower stress values were obtained in the models using a zirconia abutment (on average 964.26 MPa). When the prosthetic material used was changed, the stress values on the abutment screw was similar. Conclusions: Considering that the abutment screw is the weakest component of the implant-system, zirconia abutments can be used reliably in the maxillary first premolar region where aesthetic expectations are high. | |
| dc.identifier.doi | 10.7126/cumudj.982237 | |
| dc.identifier.endpage | 345 | |
| dc.identifier.issn | 21462852 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85125059776 | |
| dc.identifier.startpage | 337 | |
| dc.identifier.uri | https://hdl.handle.net/11452/51907 | |
| dc.identifier.uri | http://cdj.cumhuriyet.edu.tr/en/download/article-file/1922547 | |
| dc.identifier.volume | 24 | |
| dc.indexed.scopus | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Cumhuriyet Üniversitesi Diş Hekimliği Fakültesi | |
| dc.relation.journal | Cumhuriyet Dental Journal | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Glass ceramics | |
| dc.subject | Dental stress analysis | |
| dc.subject | Dental abutments | |
| dc.subject.scopus | Clinical Performance of Implant-Supported Restorations | |
| dc.title | Evaluation of biomechanical effects of prosthetic components with different materials on the abutment screw | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.contributor.department | Diş Hekimliği Fakültesi/Protetik Diş Tedavisi Ana Bilim Dalı | |
| local.indexed.at | Scopus | |
| relation.isAuthorOfPublication | 445cb9ac-17e5-4716-8945-a46301346983 | |
| relation.isAuthorOfPublication.latestForDiscovery | 445cb9ac-17e5-4716-8945-a46301346983 |
Dosyalar
Orijinal seri