Yayın:
Effect of interlayer cold joint on mechanical properties and permeability of roller compacted concrete

dc.contributor.authorBayqra, S.H.
dc.contributor.authorÖzen, S.
dc.contributor.authorMardani, A.
dc.contributor.authorRamyar, K.
dc.contributor.buuauthorMARDANİ, ALİ
dc.contributor.buuauthorBayqra, Sultan Husein
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentİnşaat Mühendisliği Ana Bilim Dalı
dc.contributor.orcid0000-0003-0326-5015
dc.contributor.scopusid58898851200
dc.contributor.scopusid57223987038
dc.date.accessioned2025-05-12T22:08:08Z
dc.date.issued2025-02-01
dc.description.abstractOne issue with layer application of roller compacted concrete (RCC) is the development of cold joints, which can cause damage to RCC structures. In this study, fly ash was used in place of 0%, 20%, 40%, and 60% of the cement or aggregate to examine the impact of interlayer cold joint formation on RCC mixtures. To promote cold joint formation, the second layer was placed and compacted with a delay of 0, 60, 120, or 180 min after the first layer. Three methods were tried for preventing cold joints from forming: one was to apply a bedding mortar to the interlayer, another was to add a set retarder admixture, and the third was to spray an adhesion-enhancing chemical additive on the surface of the first layer. Based on the 28 d specimens’ compressive and splitting-tensile strengths as well as the depth of water penetration under pressure, the most effective method was found to be applying interlayer bedding mortar. Considering 180 min delayed layer castings, the splitting-tensile and compressive strengths of the control samples decreased by 31% and 17%, respectively, while the strengths of mixtures applying interlayer bedding mortar decreased by 9% and 10%. In addition, bedding mortar treatment decreased the water permeability by 59% compared to the control. Interlayer cold joint decreased all mixtures’ moduli of elasticity, regardless of the age of the specimens. When the interlayer delay was 60 min, the modulus of elasticity decreased by 1%–4%. It was between 2% and 14%, and between 10% and 24% at 120 and 180 min for the interlayer delay. The longer the delay in placing the second RCC layer, the more detrimental the effect of the cold joint. This effect was most noticeable on mechanical and permeability properties tested with applied load or water pressure parallel to the cold joint, such as flexural and splitting tensile strengths and water penetration depth under pressure.
dc.identifier.doi10.1007/s11709-025-1145-z
dc.identifier.endpage 299
dc.identifier.issn2095-2430
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85213991164
dc.identifier.startpage284
dc.identifier.urihttps://hdl.handle.net/11452/51157
dc.identifier.volume19
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherHigher Education Press Limited Company
dc.relation.journalFrontiers of Structural and Civil Engineering
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectRoller compacted concrete
dc.subjectPermeability properties
dc.subjectMechanical properties
dc.subjectFly ash
dc.subjectCold joint
dc.subject.scopusStrength and Applications of Roller-Compacted Concrete
dc.titleEffect of interlayer cold joint on mechanical properties and permeability of roller compacted concrete
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/ İnşaat Mühendisliği Ana Bilim Dalı
local.indexed.atScopus
relation.isAuthorOfPublicationdd2de18c-4ec0-4272-8671-0094502e4353
relation.isAuthorOfPublication.latestForDiscoverydd2de18c-4ec0-4272-8671-0094502e4353

Dosyalar