Publication:
Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode

dc.contributor.authorAlǧin, Oktay
dc.contributor.authorTürkbey, Barış
dc.contributor.authorÖzmen, Evrim
dc.contributor.authorKaraoǧlanoǧlu, Mustafa
dc.contributor.authorArslan, Halil
dc.contributor.buuauthorOcakoğlu, Gökhan
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentBiyoistatistik Ana Bilim Dalı
dc.contributor.researcheridAAH-5180-2021
dc.contributor.scopusid15832295800
dc.date.accessioned2022-11-18T13:28:55Z
dc.date.available2022-11-18T13:28:55Z
dc.date.issued2013-03
dc.description.abstractPurpose: This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STY) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI). Methods: PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STY as well as in 10 control cases. The presence of STY was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared. Results: There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r] = 0.784; P = 0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STY scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1). Conclusion: 3D-SPACE can provide morphological physiological information for the evaluation of STY with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus.
dc.identifier.citationAlgin, O. vd. (2013). "Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode". Journal of Neuroradiology, 40(1), 11-18.
dc.identifier.endpage18
dc.identifier.issn0150-9861
dc.identifier.issue1
dc.identifier.pubmed22305437
dc.identifier.scopus2-s2.0-84875116692
dc.identifier.startpage11
dc.identifier.urihttps://doi.org/10.1016/j.neurad.2011.12.003
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0150986111001441
dc.identifier.urihttp://hdl.handle.net/11452/29493
dc.identifier.volume40
dc.identifier.wos000317092100002
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherJournal of Neuroradiology
dc.relation.collaborationYurt içi
dc.relation.collaborationSanayi
dc.relation.journalJournal of Neuroradiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectNeurosciences & neurology
dc.subjectRadiology, nuclear medicine & medical imaging
dc.subjectSpontaneous third ventriculostomy
dc.subjectObstructive hydrocephalus
dc.subjectMagnetic resonance imaging
dc.subject3D-space
dc.subjectPhase-contrast cine MRI
dc.subjectSingle-slab
dc.subjectCisternography
dc.subject3d-ciss
dc.subjectSpace
dc.subject3D
dc.subject.emtreeAdolescent
dc.subject.emtreeAdult
dc.subject.emtreeAged
dc.subject.emtreeAnastomosis
dc.subject.emtreeArticle
dc.subject.emtreeBrain disease
dc.subject.emtreeChild
dc.subject.emtreeCineradiography
dc.subject.emtreeClinical article
dc.subject.emtreeClinical examination
dc.subject.emtreeConsensus
dc.subject.emtreeControlled clinical trial
dc.subject.emtreeControlled study
dc.subject.emtreeDiagnostic value
dc.subject.emtreeFemale
dc.subject.emtreeHuman
dc.subject.emtreeImage display
dc.subject.emtreeIntermethod comparison
dc.subject.emtreeMale
dc.subject.emtreeNuclear magnetic resonance imaging
dc.subject.emtreeNuclear magnetic resonance scanner
dc.subject.emtreeObstructive hydrocephalus
dc.subject.emtreePhase contrast cine magnetic resonance imaging
dc.subject.emtreeProspective study
dc.subject.emtreeRadiologist
dc.subject.emtreeReliability
dc.subject.emtreeScoring system
dc.subject.emtreeSpontaneous third ventriculostomy
dc.subject.emtreeThree dimensional imaging
dc.subject.emtreeThree dimensional sampling perfection with application optimized optimized contrasts using different flip angle evolution
dc.subject.meshAdolescent
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshAlgorithms
dc.subject.meshChild
dc.subject.meshFemale
dc.subject.meshHumans
dc.subject.meshHydrocephalus
dc.subject.meshImage enhancement
dc.subject.meshImage interpretation, computer-assisted
dc.subject.meshImaging, three-dimensional
dc.subject.meshMagnetic resonance imaging
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshPilot projects
dc.subject.meshReproducibility of results
dc.subject.meshSample size
dc.subject.meshSensitivity and specificity
dc.subject.meshSurgery, computer-assisted
dc.subject.meshThird ventricle
dc.subject.meshTreatment outcome
dc.subject.meshVentriculostomy
dc.subject.scopusVentriculostomy; Hydrocephalus; Neuroendoscopy
dc.subject.wosClinical neurology
dc.subject.wosNeuroimaging
dc.subject.wosRadiology, nuclear medicine & medical imaging
dc.titleEvaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode
dc.typeArticle
dc.wos.quartileQ3 (Radiology, nuclear medicine & medical imaging)
dc.wos.quartileQ4
dc.wos.quartileQ3
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Biyoistatistik Ana Bilim Dalı
local.indexed.atPubMed
local.indexed.atWOS
local.indexed.atScopus

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: