Yayın: An approximation for response function to gamma-rays of NaI(Tl) detectors up to 1.5 MeV
| dc.contributor.buuauthor | Cengiz, Ahmet | |
| dc.contributor.department | Fen Edebiyat Fakültesi | |
| dc.contributor.department | Fizik Bölümü | |
| dc.contributor.researcherid | AAH-7446-2021 | |
| dc.contributor.scopusid | 18534116600 | |
| dc.date.accessioned | 2024-03-21T05:43:31Z | |
| dc.date.available | 2024-03-21T05:43:31Z | |
| dc.date.issued | 2008-10 | |
| dc.description.abstract | The response functions of a 7.62 x 7.62 cm Nal(Tl) scintillation detector to photons from point gamma-ray sources, 10 cm from the scintillator surface, in the energy up to 1.5 MeV, were calculated using the Monte Carlo method, applying simple approximations based on the peak to total ratio and the detector resolution. The Compton continuum of the detector response function was assumed as an isotropic (rectangular) region for the photon energies up to I MeV. In the energies between 1 and 1.5 MeV, the Compton continuum was obtained assuming a single Compton scattering with free electrons. The photopeak of the detector response function was assumed as a line. Each determined channel of the response function was distributed to Gaussian functions. The obtained response functions were compared with the experimental values and a good agreement was found. | |
| dc.identifier.citation | Cengiz, A. (2008). "An approximation for response function to gamma-rays of NaI(Tl) detectors up to 1.5 MeV". Applied Radiation and Isotopes, 66(10), 1371-1376. | |
| dc.identifier.doi | 10.1016/j.apradiso.2008.03.016 | |
| dc.identifier.endpage | 1376 | |
| dc.identifier.issn | 0969-8043 | |
| dc.identifier.issue | 10 | |
| dc.identifier.pubmed | 18486481 | |
| dc.identifier.scopus | 2-s2.0-48849117701 | |
| dc.identifier.startpage | 1371 | |
| dc.identifier.uri | https://doi.org/10.1016/j.apradiso.2008.03.016 | |
| dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0969804308001826 | |
| dc.identifier.uri | https://hdl.handle.net/11452/40534 | |
| dc.identifier.volume | 66 | |
| dc.identifier.wos | 000259385000016 | |
| dc.indexed.scopus | Scopus | |
| dc.indexed.wos | SCIE | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.relation.journal | Applied Radiation and Isotopes | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Detectors | |
| dc.subject | Functions | |
| dc.subject | Light emission | |
| dc.subject | Luminescence | |
| dc.subject | Management science | |
| dc.subject | Mathematical models | |
| dc.subject | Monte carlo methods | |
| dc.subject | Photons | |
| dc.subject | Power spectral density | |
| dc.subject | Scintillation | |
| dc.subject | Scintillation counters | |
| dc.subject | Compton | |
| dc.subject | Compton continuum | |
| dc.subject | Detector resolution | |
| dc.subject | Detector response functions | |
| dc.subject | Experimental values | |
| dc.subject | Free electrons | |
| dc.subject | Gaussian functions | |
| dc.subject | Monte Carlo method | |
| dc.subject | NaI detectors | |
| dc.subject | Nai(Tl) detector | |
| dc.subject | Peak to total ratio | |
| dc.subject | Photo peaks | |
| dc.subject | Photon energies | |
| dc.subject | Response function | |
| dc.subject | Response functions | |
| dc.subject | Scintillation detector | |
| dc.subject | Chemistry | |
| dc.subject | Nuclear science & technology | |
| dc.subject | Radiology, nuclear medicine & medical imaging | |
| dc.subject.emtree | Sodium iodide | |
| dc.subject.emtree | Article | |
| dc.subject.emtree | Compton effect | |
| dc.subject.emtree | Energy transfer | |
| dc.subject.emtree | Gamma radiation | |
| dc.subject.emtree | Monte carlo method | |
| dc.subject.emtree | Photon | |
| dc.subject.emtree | Priority journal | |
| dc.subject.emtree | Scintillation | |
| dc.subject.mesh | Computer simulation | |
| dc.subject.mesh | Computer-aided design | |
| dc.subject.mesh | Dose-response relationship, radiation | |
| dc.subject.mesh | Equipment design | |
| dc.subject.mesh | Equipment failure analysis | |
| dc.subject.mesh | Gamma cameras | |
| dc.subject.mesh | Gamma ray | |
| dc.subject.mesh | Models, chemical | |
| dc.subject.mesh | Radiation dosage | |
| dc.subject.mesh | Sodium iodide | |
| dc.subject.scopus | Detector; Radiation Detectors; Scintillation | |
| dc.subject.wos | Chemistry, inorganic & Nuclearn | |
| dc.subject.wos | Nuclear science & technology | |
| dc.subject.wos | Radiology, nuclear medicine & medical imaging | |
| dc.title | An approximation for response function to gamma-rays of NaI(Tl) detectors up to 1.5 MeV | |
| dc.type | Article | |
| dc.wos.quartile | Q2 | |
| dspace.entity.type | Publication | |
| local.contributor.department | Fen Edebiyat Fakültesi/Fizik Bölümü | |
| local.indexed.at | PubMed | |
| local.indexed.at | Scopus |
Dosyalar
Lisanslı seri
1 - 1 / 1
