Yayın:
Resolving soft X-ray absorption in energy, space and time in gaseous detectors using the VMM3a ASIC and the SRS

dc.contributor.authorScharenberg, L.
dc.contributor.authorBrunbauer, F.
dc.contributor.authorDesch, K.
dc.contributor.authorHracek, M.
dc.contributor.authorLisowska, M.
dc.contributor.authorLupberger, M.
dc.contributor.authorMuller, H.
dc.contributor.authorOliveri, E.
dc.contributor.authorPfeiffer, D.
dc.contributor.authorRopelewski, L.
dc.contributor.authorSamarati, J.
dc.contributor.authorvan Stenis, M.
dc.contributor.authorUtrobicic, A.
dc.contributor.authorVeenhof, R.
dc.contributor.buuauthorVeenhof, Robert J.
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Ana Bilim Dalı
dc.contributor.scopusid6603742499
dc.date.accessioned2025-05-13T09:11:41Z
dc.date.issued2020-10-11
dc.description.abstractThe implementation of the VMM3a Application-Specific Integrated Circuit (ASIC) into the Scalable Readout System (SRS) has opened a new domain for measurements with Micro-Pattern Gaseous Detectors (MPGDs). In the presented studies we demonstrate the capabilities of this system, specifically the time-resolution in the nanosecond regime in combination with a continuous multichannel readout and a 10-bit ADC. We can now resolve the interaction of argon fluorescence X-ray photons created in a gaseous detector and utilise these interactions to determine the electron drift velocity in our detector and to investigate the attenuation length of the fluorescence photons.
dc.identifier.doi10.1016/j.nima.2020.164310
dc.identifier.issn0168-9002
dc.identifier.scopus2-s2.0-85087591587
dc.identifier.urihttps://hdl.handle.net/11452/51978
dc.identifier.volume977
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectX-ray absorption
dc.subjectVMM3a
dc.subjectScalable readout system
dc.subjectRadiation detectors
dc.subjectMicro-pattern gaseous detectors
dc.subject.scopusGas Detectors for Particle Physics
dc.titleResolving soft X-ray absorption in energy, space and time in gaseous detectors using the VMM3a ASIC and the SRS
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Ana Bilim Dalı
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Veenhof_vd_2020
Boyut:
727.11 KB
Format:
Adobe Portable Document Format