Publication:
Comparison of biofilm formation capacities of two clinical isolates of staphylococcus epidermidis with and without icaA and icaD genes on intraocular lenses

Loading...
Thumbnail Image

Date

2017-04-01

Authors

Kıvanç, Sertaç Argun
Kıvanç, Merih
Kılıç, Volkan
Güllülü, Gülay
Özmen, Ahmet Tuncer

Journal Title

Journal ISSN

Volume Title

Publisher

Galenos Yayınevi

Research Projects

Organizational Units

Journal Issue

Abstract

Objectives: To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before.Materials and Methods: Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 degrees C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy.Results: Mean bacterial counts on the IOLs were 7.1 +/- 0.4 log 10 CFU/mL with the ICA+ isolate, and 6.7 +/- 0.8 log 10 CFU/mL with the ICA-isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p= 0.009 and p= 0.013). The highest biofilm production was obtained on IOL C (PMMA) (p< 0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p< 0.001).Conclusion: Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study.

Description

Keywords

Cataract-surgery, Postoperative endophthalmitis, Bacterial-contamination, In-vitro, Adhesion, Infections, Adherence, Population, Chamber, Reduce, Biofilm, Intraocular lenses, Staphylococcus epidermidis, Hydrophobic, Hydrophilic, Ophthalmology

Citation

Collections

2

Views

0

Downloads

Search on Google Scholar