Publication:
A method for coincidence timing resolution enhancement

dc.contributor.authorErmiş, Elif Ebru
dc.contributor.authorÇeliktaş, Cüneyt
dc.contributor.buuauthorPiliçer, Ercan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentFizik Bölümü
dc.contributor.scopusid15843878300
dc.date.accessioned2023-07-27T11:08:06Z
dc.date.available2023-07-27T11:08:06Z
dc.date.issued2016-04-27
dc.description.abstractA method including the coincidence time resolution improvement for a TOF/positron emission tomography system was suggested. The spectrometer for this aim was composed of two NaI(Tl) and two plastic scintillation detectors. Experimental results were supported by FLUKA Monte Carlo simulation program by constructing the detector setup in software medium. Present experimental results verified our previous results and conclusions obtained from the suggested method. It was concluded that better resolutions would help the improvement not only on the TOF gain but also on the spatial resolution, leading to better images and helping the Physician in his/her diagnosis and treatment.
dc.description.sponsorshipEge Üniversitesi - 99 BIL 001 / 14 FEN 026
dc.identifier.citationErmiş, E. E. vd. (2016). "A method for coincidence timing resolution enhancement". Review of Scientific Instruments, 87(5).
dc.identifier.issn0034-6748
dc.identifier.issn1089-7623
dc.identifier.issue5
dc.identifier.pubmed27250420
dc.identifier.scopus2-s2.0-84971280038
dc.identifier.urihttps://doi.org/10.1063/1.4948925
dc.identifier.urihttps://pubs.aip.org/aip/rsi/article-abstract/87/5/053504/982661/A-method-for-coincidence-timing-resolution?redirectedFrom=fulltext
dc.identifier.urihttp://hdl.handle.net/11452/33300
dc.identifier.volume87
dc.identifier.wos000379187600055
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherAIP Publishing
dc.relation.bapOUAP(F)-2012/26
dc.relation.collaborationYurt içi
dc.relation.journalReview of Scientific Instruments
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.relation.tubitak197T087
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectInstruments & Instrumentation
dc.subjectPhysics
dc.subjectTime-of-flight
dc.subjectPositron-emission-tomography
dc.subjectTo-noise ratio
dc.subjectPet
dc.subjectSystems
dc.subjectDetector
dc.subjectBenefit
dc.subjectComputer software
dc.subjectImage enhancement
dc.subjectIntelligent systems
dc.subjectSodium Iodide
dc.subjectTiming circuits
dc.subjectEmission tomography
dc.subjectPlastic scintillation detectors
dc.subjectSpatial resolution
dc.subjectTime resolution improvements
dc.subjectTiming resolutions
dc.subjectMonte Carlo methods
dc.subject.scopusPositron Emission Tomography; Lutetium Orthosilicate; Scintillator
dc.subject.wosInstruments & instrumentation
dc.subject.wosPhysics, applied
dc.titleA method for coincidence timing resolution enhancement
dc.typeArticle
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Fizik Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: