Publication:
Experimental evaluation of wind loads on a ground-mounted solar panel of various ground clearances and Reynolds numbers

dc.contributor.authorYemenici, Onur
dc.contributor.buuauthorYEMENİCİ, ONUR
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.researcheridGKS-5251-2022
dc.date.accessioned2024-06-27T10:57:21Z
dc.date.available2024-06-27T10:57:21Z
dc.date.issued2021-12-01
dc.description.abstractThe wind loads on a stand-alone solar panel and flow field behind the panel were experimentally investigated in a wind tunnel under the influence of ground clearance and Reynolds number. The experiments were carried out at the chord Reynolds number of 6.4x10(4), 9.6x10(4), and 1.3x10(5) encompassing turbulent flows and dimensionless ground clearance of 0, 0.5 and 0.6. The velocity and turbulence intensities were measured by a constant-temperature hot wire anemometer, and a pressure scanner system was used to static pressure measurements. It was found that the wind loads on the solar panel increased with ground clearance, while changed within a range of the uncertainties of the method with Reynolds number. So, the design-relevant wind loads were independent of the Reynolds number for the present test configurations, but they were significantly affected by the ground clearance. The velocity profiles demonstrated that the length of the recirculation region behind the panel increased with the reduction of the ground clearance, while decreased from the middle of the panel to the near edges, which is consistent with the pressure measurements.
dc.identifier.doi10.1007/s12046-021-01718-w
dc.identifier.eissn0973-7677
dc.identifier.issn0256-2499
dc.identifier.issue4
dc.identifier.urihttps://doi.org/10.1007/s12046-021-01718-w
dc.identifier.urihttps://link.springer.com/article/10.1007/s12046-021-01718-w
dc.identifier.urihttps://hdl.handle.net/11452/42517
dc.identifier.volume46
dc.identifier.wos000705860700006
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherSpringer
dc.relation.journalSadhana-academy Proceedings in Engineering Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectScaling parameters
dc.subjectArrays
dc.subjectSimulation
dc.subjectCoefficients
dc.subjectHeliostats
dc.subjectRoofs
dc.subjectWind load
dc.subjectSolar panel
dc.subjectGround clearance
dc.subjectWind tunnel
dc.subjectTurbulent flows
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectEngineering, multidisciplinary
dc.subjectEngineering
dc.titleExperimental evaluation of wind loads on a ground-mounted solar panel of various ground clearances and Reynolds numbers