Drying kinetics and energy-exergy analysis of an experimental heat pump dryer utilized horseshoe heat recovery heat pipes for drying different grapes

dc.contributor.authorTunckal, Cuneyt
dc.contributor.authorDirek, Mehmet
dc.contributor.authorDoymaz, İbrahim
dc.contributor.authorGöksel, Zekiye
dc.contributor.buuauthorAtak, Arif
dc.contributor.buuauthorATAK, ARİF
dc.contributor.departmentZiraat Fakültesi
dc.contributor.departmentBahçe Bitkileri Bölümü
dc.contributor.orcid0000-0001-7251-2417
dc.contributor.researcheridJ-2913-2018
dc.date.accessioned2024-11-22T05:45:10Z
dc.date.available2024-11-22T05:45:10Z
dc.date.issued2022-10-06
dc.description.abstractIn this study, nine different seeded and seedless grape cultivars (Vitis spp) were dried in a closed circuit heat pump-drying (HPD) system. The system's drying performance was determined for each grape cultivar, and exergy analysis was performed. The evaporator efficiency increases when the external condenser is in the "on" position. This revealed that when the system reached the desired drying temperature, the longer the external condenser stayed in the "on" position, the more moisture can be drawn from the product. The heat pump highest coefficient of performance total (COPtotal,hp) and system coefficient of performance total (COPtotal,sys) were found to be 3.714 and 3.035, respectively, in the external condenser "on" position. The highest exergy efficiency values of compressor, condenser, TXV, evaporator and drying cabined were found to be 68 %, 75.41 %, 92.43 %, 77.35 % and 78.28 % respectively, when the external condenser "on" position. The highest exergy efficiencies were determined 75.75 %, 69.81 %, 87.5 %, 86.65 % and 80.46 % respectively, when the external condenser "off" position. The experiments of were evaluated in order to study the drying characteristics in HPD system. The changes in moisture ratio during the drying process were compared by six thin-layer drying models and then assessed in terms of various statistical criteria like root-mean-square-error (RMSE), diminished chi-square (chi 2), and determination constant(R2). Fick's second law of diffusion was used to obtained diffusivity of effective -moisture values, and they were found to range between 4.715 x 10-11 and 1.280 x 10-10 m2/s.
dc.description.sponsorshipYalova Ataturk Horticultural Central Research Institute
dc.description.sponsorshipYalova Üni,versitesi -- 2020/AP/0001
dc.identifier.doi10.1016/j.tsep.2022.101487
dc.identifier.issn2451-9049
dc.identifier.scopus2-s2.0-85139328311
dc.identifier.urihttps://doi.org/10.1016/j.tsep.2022.101487
dc.identifier.urihttps://hdl.handle.net/11452/48322
dc.identifier.volume36
dc.identifier.wos000867654600004
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherElsevier
dc.relation.journalThermal Science And Engineering Progress
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectQuality characteristics
dc.subjectSimulation
dc.subjectSystem
dc.subjectLeaves
dc.subjectCop
dc.subjectDrying
dc.subjectExergy efficiency
dc.subjectHeat pump
dc.subjectMoisture ratio
dc.subjectVitis spp
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectTechnology
dc.subjectThermodynamics
dc.subjectEnergy & fuels
dc.subjectEngineering, mechanical
dc.subjectEngineering
dc.subjectMechanics
dc.titleDrying kinetics and energy-exergy analysis of an experimental heat pump dryer utilized horseshoe heat recovery heat pipes for drying different grapes
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentZiraat Fakültesi/Bahçe Bitkileri Bölümü
local.indexed.atWOS
local.indexed.atScopus
relation.isAuthorOfPublicationfdbf52b1-d830-4931-9750-1580bc7badca
relation.isAuthorOfPublication.latestForDiscoveryfdbf52b1-d830-4931-9750-1580bc7badca

Files