Publication:
Maximum torque and muscle strain while using screwdrivers with clean and contaminated surfaces in bi-directional use

dc.contributor.authorKeller, Elke Simon
dc.contributor.authorStrasser, Helmut
dc.contributor.buuauthorÖzalp, Besim Türker
dc.contributor.departmentMühendislik Mimarlık Fakültesi
dc.contributor.departmentEndüstri Mühendisliği Bölümü
dc.contributor.researcheridAAG-9678-2021
dc.date.accessioned2024-04-01T05:47:50Z
dc.date.available2024-04-01T05:47:50Z
dc.date.issued2007
dc.description.abstractThe use of manual screwdrivers is still an important part of the work of, e. g., car mechanics or in the furniture section. Tightening or loosening screws often requires high torque strength. Therefore, the ergonomic design of the screwdriver handle helps to fulfill the working task by reducing physiological costs for the muscles of the upper extremity as well as complaints like blisters and pressure marks at the fingers and in the palm of the hand. In a series of screwdriver tests with 5 various handles (4 ergonomically designed and one "old-fashioned" handle as reference), bi-directional exertions with clean and oil-contaminated hands were demanded to simulate typical work tasks. Twelve male subjects (Ss), all right-handed, between the ages of 15 and 32, participated in standardized working tests during which the maximum achievable torque was determined. Simultaneously, electromyographic activities (EA) of 4 muscles involved in the working tasks were recorded, processed, and standardized. Significant differences between the standardized electromyographic activities of the muscles investigated were obtained depending on the direction of rotation. Also substantial differences between maximum torque strength were determined for pronation and supination, and for clean and contaminated contact surfaces. The results of this study were mostly consistent with those of the study described in Chapter 10.1 and, therefore, enable testing the reliability of methods applied.
dc.identifier.citationÖzalp, B. T. vd. (2007). "Maximum torque and muscle strain while using screwdrivers with clean and contaminated surfaces in bi-directional use". Assessment of the Ergonomic Quality of Hand-held Tools and Computer Input Devices, 1, 173-181.
dc.identifier.endpage181
dc.identifier.isbn978-1-58603-788-8
dc.identifier.issn1874-8694
dc.identifier.startpage173
dc.identifier.urihttps://hdl.handle.net/11452/40865
dc.identifier.volume1
dc.identifier.wos000271657400014
dc.indexed.wosBKCISSH
dc.language.isoen
dc.publisherIOS Press
dc.relation.journalAssessment of the Ergonomic Quality of Hand-held Tools and Computer Input Devices
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEngineering
dc.subject.wosErgonomics
dc.titleMaximum torque and muscle strain while using screwdrivers with clean and contaminated surfaces in bi-directional use
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Mimarlık Fakültesi/Endüstri Mühendisliği Bölümü
local.indexed.atPubMed

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: