Yayın: Evaluation of energy resolution by changing angle and position of incident photon in a lyso calorimeter
Dosyalar
Tarih
Kurum Yazarları
Saad, Ahmed Mohamed Elfatih
Yazarlar
Saad, A. M. E.
Koçak, Fatma
Danışman
Dil
Türü
Yayıncı:
Jagiellonian Univ Press
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Özet
In this paper, we investigate the effect on energy resolution from changing the angle and the position of incidence photon for a 5 x 5 crystal matrix built with (25 x 25 x 200) mm(3) LYSO scintillating crystals. Those crystals have been proposed for the electromagnetic calorimeter of the Turkish Accelerator Center-Particle Factory (TAC-PF) detector. The energy resolution was obtained as sigma(E)/E = 0.42%/ root E/GeV circle plus 1.60% at the center of the matrix in the energy range of 50 MeV to 2 GeV. When we examined the dependence of the energy resolution on the incidence angle of the photon, resolution began to deteriorate at angles greater than 2 degrees on the 5 x 5 crystal matrix. Moreover, energy resolution at the corners of the central crystal was worse than at the center of the central crystal by a factor of 1.3 at 50 MeV and 1.1 at 2 GeV.
Açıklama
Kaynak:
Anahtar Kelimeler:
Konusu
Crystal, Simulation, Science & technology, Physical sciences, Physics, multidisciplinary, Physics