Publication:
Seismic vulnerability and preservation of historical masonry monumental structures

dc.contributor.authorSezen, Halil
dc.contributor.buuauthorDoğangün, Adem
dc.contributor.departmentMühendislik Mimarlık Fakültesi
dc.contributor.departmentİnşaat Mühendisliği Bölümü
dc.contributor.orcid0000-0002-1867-7103
dc.contributor.researcheridAAR-6126-2020
dc.contributor.scopusid6602349830
dc.date.accessioned2021-12-14T07:14:14Z
dc.date.available2021-12-14T07:14:14Z
dc.date.issued2012-02
dc.description.abstractSeismic damage and vulnerability of five historical masonry structures surveyed after the 1999 Kocaeli and Duzce, Turkey earthquakes are discussed in this paper. The structures are located in two neighboring cities that have been struck by five very large (M-s >= 7.0) earthquakes during the 20th century alone. Older masonry mosques with arches and domes and their masonry minarets (slender towers) were among the most affected structures in this highly seismic region. While some of the religious and historical structures had virtually no damage, most structures suffered significant damage or collapsed. In the city of Bolu, for example, approximately 600-year-old Imaret, 500-year-old Kadi, 250-year-old Sarachane, and 100-year-old Yildirim Bayezid mosques suffered substantial structural damage after the 1999 earthquakes. Another historical mosque surveyed in Duzce partially collapsed. Most common factors contributing to deterioration of historical structures are also presented. Furthermore, a brief overview of issues associated with analysis and modeling of historical masonry structures is provided.
dc.identifier.citationDoğangün, A. ve Sezen, H. (2012). "Seismic vulnerability and preservation of historical masonry monumental structures". Earthquakes and Structures, 3(1), 83-95.
dc.identifier.endpage95
dc.identifier.issn2092-7614
dc.identifier.issn2092-7622
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84856626198
dc.identifier.startpage83
dc.identifier.urihttps://doi.org/10.12989/eas.2012.3.1.083
dc.identifier.urihttp://koreascience.or.kr/article/JAKO201215541636710.page
dc.identifier.urihttp://hdl.handle.net/11452/23230
dc.identifier.volume3
dc.identifier.wos000309504100005
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherTechno-Press
dc.relation.collaborationYurt dışı
dc.relation.journalEarthquakes and Structures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEngineering
dc.subjectSeismic damage
dc.subjectHistorical turkish mosques
dc.subjectMasonry
dc.subjectDeterioration
dc.subjectEarthquake
dc.subjectDynamic-response
dc.subjectPerformance
dc.subjectKocaeli
dc.subjectGeophysics
dc.subjectMasonry materials
dc.subjectSeismology
dc.subjectSurveys
dc.subjectAnalysis and modeling
dc.subjectHighly seismic regions
dc.subjectHistorical structures
dc.subjectMasonry structures
dc.subjectSeismic damage
dc.subjectSeismic vulnerability
dc.subjectTurkishs
dc.subjectEarthquakes
dc.subject.scopusMasonry; Minaret; Historic Sites
dc.subject.wosEngineering, civil
dc.subject.wosEngineering, geological
dc.titleSeismic vulnerability and preservation of historical masonry monumental structures
dc.typeArticle
dc.wos.quartileQ1
dspace.entity.typePublication
local.contributor.departmentMühendislik Mimarlık Fakültesi/İnşaat Mühendisliği Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Doğangün_Sezen_2012
Size:
4.53 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: