Yayın:
Minimally invasive plate osteosynthesis for short oblique diaphyseal tibia fractures: Does fracture site affect the outcomes?

dc.contributor.authorEken, Gökay
dc.contributor.buuauthorErmutlu, Cenk
dc.contributor.buuauthorDurak, Kemal
dc.contributor.buuauthorAtıcı, Teoman
dc.contributor.buuauthorSarısözen, Bartu
dc.contributor.buuauthorÇakar, Adnan
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentOrtopedi ve Travmatoloji Ana Bilim Dalı
dc.contributor.researcheridABI-7283-2020
dc.contributor.researcheridAAB-2795-2021
dc.contributor.researcheridA-5095-2018
dc.contributor.scopusid57195109967
dc.contributor.scopusid54392665300
dc.contributor.scopusid6602850051
dc.contributor.scopusid7801647288
dc.contributor.scopusid55890736200
dc.contributor.scopusid57219550849
dc.date.accessioned2022-12-22T06:03:34Z
dc.date.available2022-12-22T06:03:34Z
dc.date.issued2020-10-22
dc.description.abstractObjective To report the results of patients with short oblique diaphyseal tibia fractures treated with minimally invasive plate osteosynthesis (MIPO). The secondary aim was to understand the effect of fracture location (midshaft or distal 1/3) on outcomes. Methods Twenty-eight patients with short oblique (>30 degrees) tibial shaft fractures (AO/OTA 42A2) treated with plate and MIPO technique between 2015 and 2019 were retrospectively assessed. Age, gender, follow-up time, fracture type (open or closed), operation time, postoperative infection rate, union time, ankle joint range of motion, and complications were analyzed. Patients' radiographs at a minimum 1-year follow-up were evaluated for malunion, nonunion, and implant-related complications. Results Mean age and follow-up time were 47.0 +/- 15.7 years and 18.3 +/- 12.1 months, respectively. Mean bone union time was 3.66 +/- 1.04 months in middle 1/3 diaphysis and 4.23 +/- 1.48 months in distal 1/3 tibia fractures. Seven (25%) patients developed superficial infections. Mean union time, malunion rate, coronal and sagittal angulation, operation length, and infection rate were similar between the groups. Conclusion MIPO is an effective method for treatment of short oblique diaphyseal tibia fractures, and results in few complications. Both distal and midshaft fractures have similar union and malunion rates.
dc.identifier.citationEken, G. vd. (2020). "Minimally invasive plate osteosynthesis for short oblique diaphyseal tibia fractures: Does fracture site affect the outcomes?". Journal of International Medical Research, 48(10).
dc.identifier.doi10.1177/0300060520965402
dc.identifier.issn0300-0605
dc.identifier.issn1473-2300
dc.identifier.issue10
dc.identifier.pubmed33086906
dc.identifier.scopus2-s2.0-85093841043
dc.identifier.urihttps://doi.org/10.1177/0300060520965402
dc.identifier.urihttps://journals.sagepub.com/doi/10.1177/0300060520965402
dc.identifier.urihttp://hdl.handle.net/11452/30028
dc.identifier.volume48
dc.identifier.wos000586465000001
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherSage Publications
dc.relation.collaborationSanayi
dc.relation.journalJournal of International Medical Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTibia fracture
dc.subjectMinimally invasive percutaneous osteosynthesis
dc.subjectPlate osteosynthesis
dc.subjectBone union
dc.subjectNonunion
dc.subjectMalunion
dc.subjectSingle-center
dc.subjectDistal meta
dc.subjectMetaphyseal
dc.subjectResearch & experimental medicine
dc.subjectPharmacology & pharmacy
dc.subject.emtreeAdult
dc.subject.emtreeAge distribution
dc.subject.emtreeArticle
dc.subject.emtreeClinical article
dc.subject.emtreeClinical assessment
dc.subject.emtreeClinical effectiveness
dc.subject.emtreeClinical evaluation
dc.subject.emtreeClinical feature
dc.subject.emtreeClinical outcome
dc.subject.emtreeControlled study
dc.subject.emtreeFemale
dc.subject.emtreeFollow up
dc.subject.emtreeFracture nonunion
dc.subject.emtreeHuman
dc.subject.emtreeMale
dc.subject.emtreeMinimally invasive surgery
dc.subject.emtreeOperation duration
dc.subject.emtreePlate fixation
dc.subject.emtreePostoperative infection
dc.subject.emtreeRange of motion
dc.subject.emtreeRetrospective study
dc.subject.emtreeSex difference
dc.subject.emtreeSurgical infection
dc.subject.emtreeSurgical technique
dc.subject.emtreeTibia shaft fracture
dc.subject.emtreeBone plate
dc.subject.emtreeDiagnostic imaging
dc.subject.emtreeFracture healing
dc.subject.emtreeMinimally invasive surgery
dc.subject.emtreeOsteosynthesis
dc.subject.emtreeTibia
dc.subject.emtreeTibia fracture
dc.subject.emtreeTreatment outcome
dc.subject.meshBone plates
dc.subject.meshFracture fixation, internal
dc.subject.meshFracture healing
dc.subject.meshHumans
dc.subject.meshMinimally invasive surgical procedures
dc.subject.meshRetrospective studies
dc.subject.meshTibia
dc.subject.meshTibial fractures
dc.subject.meshTreatment outcome
dc.subject.scopusIntramedullary Nailing; Tibial Fractures; Osteosynthesis
dc.subject.wosMedicine, research & experimental
dc.subject.wosPharmacology & pharmacy
dc.titleMinimally invasive plate osteosynthesis for short oblique diaphyseal tibia fractures: Does fracture site affect the outcomes?
dc.typeArticle
dc.wos.quartileQ4
dc.wos.quartileQ4
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Ortopedi ve Travmatoloji Ana Bilim Dalı
local.indexed.atPubMed
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Ermutlu_vd_2020.pdf
Boyut:
455.32 KB
Format:
Adobe Portable Document Format
Açıklama

Lisanslı seri

Şimdi gösteriliyor 1 - 1 / 1
Placeholder
Ad:
license.txt
Boyut:
1.71 KB
Format:
Item-specific license agreed upon to submission
Açıklama