Publication:
Determination of total and fluoride bound aluminium in tea infusions by ion selective electrode and flame atomic absorption spectrometry

dc.contributor.authorErdemoğlu, Sema
dc.contributor.authorTürkdemir, Haluk
dc.contributor.buuauthorGüçer, Şeref
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentKimya Bölümü
dc.contributor.orcid0000-0003-0610-2019
dc.contributor.scopusid36849130600
dc.date.accessioned2021-07-30T09:09:15Z
dc.date.available2021-07-30T09:09:15Z
dc.date.issued2000
dc.description.abstractSpeciation of metallic compunds is important especially for their bioavailability. In this present study fluoride bound aluminium species were determined in tea infusion. Total aluminium was measured using name atomic absorption spectrometry (FAAS). Free fluoride and total fluoride were measured by fluoride selective ion electrode (FISE) with the assistance of TISAB buffer solution used for adjustment of pH and total ionic strength, and ALCOA buffer solution which decomposes all of the Al-fluoride complexes in solution. During the studies, the effects of pH and time on the formation of Al-F complexes and interference of some metal ions found in tea infusion such as Al3+, Mg2+, Fe2+, Fe3+ and Mn2+ on the concentration of free fluoride were investigated. The concentration of each Al-fluoride complexes in tea infusion were determined indirectly by calculation using pF-Mole Fraction Diagram. It was found that 1.13+/-0.15 mg l(-1) of 12.00+/-0.86 mg l(-1) total aluminium is fluoride bound aluminium, which means that approximately 10% of total aluminium in tea infusion is complexed with fluoride.
dc.identifier.citationErdemoğlu, S. vd. (2000). "Determination of total and fluoride bound aluminium in tea infusions by ion selective electrode and flame atomic absorption spectrometry". Analytical Letters, 33(8), 1513-1529.
dc.identifier.endpage1529
dc.identifier.issn0003-2719
dc.identifier.issue8
dc.identifier.scopus2-s2.0-0343618561
dc.identifier.startpage1513
dc.identifier.urihttps://doi.org/10.1080/00032710008543140
dc.identifier.urihttps://www.tandfonline.com/doi/abs/10.1080/00032710008543140
dc.identifier.urihttp://hdl.handle.net/11452/21340
dc.identifier.volume33
dc.identifier.wos000087683300006
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherMarcel Dekker Inc
dc.relation.collaborationYurt içi
dc.relation.journalAnalytical Letters
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectChemistry
dc.subjectAluminium-fluoride complexes
dc.subjectAl speciation
dc.subjectSpeciation
dc.subjectTea infusion
dc.subjectFluoride selective electrode
dc.subjectChromatography
dc.subjectWaters
dc.subject.emtreeAtomic absorption spectrometry
dc.subject.emtreeBioavailability
dc.subject.emtreeCalibration
dc.subject.emtreeComplex formation
dc.subject.emtreeDecomposition
dc.subject.emtreeIon pair chromatography
dc.subject.emtreeIonic strength
dc.subject.emtreeMetal binding
dc.subject.emtreeSpecies difference
dc.subject.emtreeTea
dc.subject.emtreeAluminum
dc.subject.emtreeFluoride
dc.subject.emtreeMagnesium
dc.subject.emtreeManganese
dc.subject.scopusTea; Camellia Sinensis; Fluorosis
dc.subject.wosChemistry, analytical
dc.titleDetermination of total and fluoride bound aluminium in tea infusions by ion selective electrode and flame atomic absorption spectrometry
dc.typeArticle
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Kimya Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: