Yayın: Monte Carlo calculations for photon attenuation studies on different solid phantom materials
Dosyalar
Tarih
Kurum Yazarları
Tarım, Urkiye Akar
Gürler, Orhan
Yazarlar
Gündoğdu, Özcan
Danışman
Dil
Türü
Yayıncı:
Polish Acad Sciences Inst Physics
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Özet
The linear attenuation coefficients of water and some solid phantom materials, namely of solid water RMI-457, of plastic water, of RW3 solid water, and of Perspex were determined by Monte Carlo calculations, for gamma-ray photons with energies of 59.5, 80.9, 140.5, 356.5, 661.6, 1173.2, and 1332.5 keV. The calculated values were compared with the experimental results presented by other researchers and with theoretical values obtained using the XCOM database. Good agreement was observed between the calculations, the experimental, and the theoretical values. The results indicate that the process in Monte Carlo code can be followed to determine the equivalency of other materials at several energies. Three shielding factors such as half-value layer, tenth-value layer, and mean free path were calculated at all considered gamma-ray energies.
Açıklama
Bu çalişma, 19-24, Ekim 2016 tarihlerinde Antalya[Türkiye]’de düzenlenen 3.International Conference on Computational and Experimental Science and Engineering (ICCESEN) Kongresi‘nde bildiri olarak sunulmuştur.
Kaynak:
Anahtar Kelimeler:
Konusu
Physics, Gamma-ray transmission, Coefficients, Glasses, Monte carlo methods, Photons, Calculated values, Gamma-ray energy, Gamma-ray photons, Linear attenuation coefficients, Monte carlo calculation, Monte Carlo codec, Photon attenuation, Theoretical values, Gamma rays
Alıntı
Gündoğdu, Ö. vd. (2017). ''Monte Carlo calculations for photon attenuation studies on different solid phantom materials''. Acta Physica Polonica A, 132(3), Special Issue, Part 2,1032-1035.