Yayın: Simulation of LYSO crystal for the TAC-PF electromagnetic calorimeter
| dc.contributor.buuauthor | Koçak, Fatma | |
| dc.contributor.buuauthor | Tapan, İlhan | |
| dc.contributor.department | Fen Edebiyat Fakültesi | |
| dc.contributor.department | Fizik Bölümü | |
| dc.contributor.orcid | 0000-0002-4756-9988 | |
| dc.contributor.researcherid | AAE-3350-2022 | |
| dc.contributor.scopusid | 15843834900 | |
| dc.contributor.scopusid | 8905787000 | |
| dc.date.accessioned | 2023-01-27T06:52:08Z | |
| dc.date.available | 2023-01-27T06:52:08Z | |
| dc.date.issued | 2017 | |
| dc.description | Bu çalışma, 01-03 Haziran 2016 tarihleri arasında İstanbul[Türkiye]’da düzenlenen 6. Congress and Exhibition on International Advances in Applied Physics and Materials Science (APMAS)’da bildiri olarak sunulmuştur. | |
| dc.description.abstract | In addition to PWO and CsI(Tl) crystals, cerium doped LYSO crystal is considered for the electromagnetic calorimeter part of the Turkish Accelerator Center Particle Factory (TAC-PF) detector, because of its high light yield, fast decay time and good radiation hardness. In this work, LYSO crystals arranged in 3 x 3 and 5 x 5 matrices have been simulated against photons in the energy range between 50 MeV and 2 GeV, using Geant4 simulation code. Energy resolutions have been estimated considering the contribution of photoelectron statistics coming from the avalanche and PIN photodiodes. | |
| dc.identifier.citation | Koçak, F. ve Tapan, İ. (2017). ''Simulation of LYSO crystal for the TAC-PF electromagnetic calorimeter''. Acta Physica Polonica A, 131(3), Special Issue, 527-529. | |
| dc.identifier.doi | 10.12693/APhysPolA.131.527 | |
| dc.identifier.endpage | 529 | |
| dc.identifier.issn | 0587-4246 | |
| dc.identifier.issue | 3, Special Issue | |
| dc.identifier.scopus | 2-s2.0-85018681665 | |
| dc.identifier.startpage | 527 | |
| dc.identifier.uri | https://doi.org/10.12693/APhysPolA.131.527 | |
| dc.identifier.uri | http://przyrbwn.icm.edu.pl/APP/PDF/131/a131z3p52.pdf | |
| dc.identifier.uri | 1898-794X | |
| dc.identifier.uri | http://hdl.handle.net/11452/30680 | |
| dc.identifier.volume | 131 | |
| dc.identifier.wos | 000400905500052 | |
| dc.indexed.wos | SCIE | |
| dc.indexed.wos | CPCIS | |
| dc.language.iso | en | |
| dc.publisher | Polish Acad Sciences Inst Physics | |
| dc.relation.bap | BAP | |
| dc.relation.journal | Acta Physica Polonica A | |
| dc.relation.publicationcategory | Konferans Öğesi - Uluslararası | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Physics | |
| dc.subject | 29.40.Mc | |
| dc.subject | 02.70.Uu | |
| dc.subject | High-energy-physics | |
| dc.subject | Large-size lso | |
| dc.subject | Damage | |
| dc.subject | Belle | |
| dc.subject | Calorimeters | |
| dc.subject | Photons | |
| dc.subject | Readout systems | |
| dc.subject | Center particles | |
| dc.subject | Electromagnetic calorimeter | |
| dc.subject | Energy ranges | |
| dc.subject | Energy resolutions | |
| dc.subject | GEANT4 simulation | |
| dc.subject | LYSO crystals | |
| dc.subject | Pin photodiode | |
| dc.subject | Radiation hardness | |
| dc.subject | High energy physics | |
| dc.subject.scopus | Avalanche Photodiodes; Dark Currents; Calorimeters | |
| dc.subject.wos | Physics, multidisciplinary | |
| dc.title | Simulation of LYSO crystal for the TAC-PF electromagnetic calorimeter | |
| dc.type | Article | |
| dc.type.subtype | Proceedings Paper | |
| dc.wos.quartile | Q3 | |
| dspace.entity.type | Publication | |
| local.contributor.department | Fen Edebiyat Fakültesi/Fizik Bölümü | |
| local.indexed.at | Scopus | |
| local.indexed.at | WOS |
