Yayın:
Determination of setting times of mortar mixtures prepared with cement having different c3a ratios

dc.contributor.authorKarakuzu, Kemal
dc.contributor.authorKobya, Veysel
dc.contributor.authorMardani, Ali
dc.contributor.buuauthorKarakuzu, Kemal
dc.contributor.buuauthorKobya, Veysel
dc.contributor.buuauthorMARDANİ, ALİ
dc.contributor.departmentMühendislik Fakültesi
dc.contributor.departmentİnşaat Mühendisliği Bölümü
dc.contributor.orcid0000-0002-1023-3962
dc.contributor.orcid0000-0003-0326-5015
dc.contributor.scopusid57220604234
dc.contributor.scopusid57193327302
dc.contributor.scopusid58898851200
dc.date.accessioned2025-05-13T06:40:51Z
dc.date.issued2022-01-01
dc.description.abstractThe duration of concrete transportation to the construction site, its workability and formwork removal time are significantly affected by the setting time of cement. Therefore, it is of great importance to know the initial and final setting times of concrete mixtures in construction applications. According to the literature survey, the setting time of cementitious systems is generally determined on cement paste mixture by the Vicat test. However, it was understood that a limited number of studies were carried out on the determination of the setting time using concrete mixtures. In this study, the effect of cement C3A ratio variation on the initial and final setting times of cementitious systems was determined using mortar mixtures. For this purpose, mortar mixtures were prepared by using cement having four different C3A content (2%, 3%, 6% and 9%). The ratios of water/cement and sand/cement as well as slump-flow values were kept constant as 0.485, 2.75 and 27±2 cm, respectively. In order to provide the desired flowability, polycarboxylate ether -based water-reducing admixture (PCE) was used. The initial and final setting times of the mortar mixtures were determined using a concrete penetrometer equipment. According to the results, PCE demand to provide the target slump-flow value increased by increasing the cement C3A content. In addition, the setting time values reduction was observed with the increase of cement C3A content. It was determined that the results obtained are compatible with the literature.
dc.identifier.doi10.55549/epstem.1225021
dc.identifier.endpage143
dc.identifier.isbn[9786057283245]
dc.identifier.issn26023199
dc.identifier.scopus2-s2.0-85146561199
dc.identifier.startpage139
dc.identifier.urihttps://hdl.handle.net/11452/51739
dc.identifier.urihttp://www.epstem.net/en/download/article-file/2855766
dc.identifier.volume21
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherISRES Publishing
dc.relation.journalEurasia Proceedings of Science, Technology, Engineering and Mathematics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSetting time
dc.subjectPenetrometer
dc.subjectPCE requirement
dc.subjectC3A
dc.subject.scopusSuperplasticizer; Adsorption; Rheology
dc.titleDetermination of setting times of mortar mixtures prepared with cement having different c3a ratios
dc.typeconferenceObject
dc.type.subtypeConference Paper
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/İnşaat Mühendisliği Bölümü
local.indexed.atScopus
relation.isAuthorOfPublicationdd2de18c-4ec0-4272-8671-0094502e4353
relation.isAuthorOfPublication.latestForDiscoverydd2de18c-4ec0-4272-8671-0094502e4353

Dosyalar

Orijinal seri

Şimdi gösteriliyor 1 - 1 / 1
Küçük Resim
Ad:
Karakuzu_vd_2022.pdf
Boyut:
511.52 KB
Format:
Adobe Portable Document Format