Publication:
The effects of the Trendelenburg position and the valsalva manoeuvre on internal jugular vein diameter and placement in children

dc.contributor.buuauthorDinçyürek, Gamze Naime
dc.contributor.buuauthorMoğol, Elif Basağan
dc.contributor.buuauthorTürker, Gürkan
dc.contributor.buuauthorYavascaoğlu, Belgin
dc.contributor.buuauthorGurbet, Alp
dc.contributor.buuauthorKaya, Fatma Nur
dc.contributor.buuauthorMoustafa, Bachri Ramadan
dc.contributor.buuauthorYazıcı, Tolga
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentAnesteziyoloji Ana Bilim Dalı
dc.contributor.orcid0000-0002-6503-8232
dc.contributor.orcid0000-0002-3019-581X
dc.contributor.researcheridAAI-6642-2021
dc.contributor.researcheridA-7994-2018
dc.contributor.researcheridAAI-7914-2021
dc.contributor.researcheridAAG-9356-2021
dc.contributor.researcheridAAI-8213-2021
dc.contributor.researcheridCMM-0680-2022
dc.contributor.researcheridDHL-3236-2022
dc.contributor.researcheridIOJ-8866-2023
dc.contributor.scopusid56786378700
dc.contributor.scopusid23982134100
dc.contributor.scopusid7003400116
dc.contributor.scopusid6602742300
dc.contributor.scopusid35618853300
dc.contributor.scopusid7003619647
dc.contributor.scopusid56786155100
dc.contributor.scopusid56682825100
dc.date.accessioned2024-02-06T05:41:21Z
dc.date.available2024-02-06T05:41:21Z
dc.date.issued2015-08
dc.description.abstractINTRODUCTION We compared the effects of various surgical positions, with and without the Valsalva manoeuvre, on the diameter of the right internal jugular vein (RIJV). METHODS We recruited 100 American Society of Anesthesiologists physical status class I patients aged 2-12 years. The patients' heart rate, blood pressure, peripheral oxygen saturation and end-tidal CO2 pressure were monitored. Induction of anaesthesia was done using 1% propofol 10 mg/mL and fentanyl 2 mu g/kg, while maintenance was achieved with 2% sevoflurane in a mixture of 50/50 oxygen and air (administered via a laryngeal mask airway). The RIJV diameter was measured using ultrasonography when the patient was in the supine position. Thereafter, it was measured when the patient was in the supine position + Valsalva, followed by the Trendelenburg, Trendelenburg + Valsalva, reverse Trendelenburg, and reverse Trendelenburg + Valsalva positions. A 15 degrees depression or elevation was applied for the Trendelenburg position, and an airway pressure of 20 cmH(2)O was applied in the Valsalva manoeuvre. During ultrasonography, the patient's head was tilted 20 degrees to the left. RESULTS When compared to the mean RIJV diameter in the supine position, the mean RIJV diameter was significantly greater in all positions (p < 0.001) except for the reverse Trendelenburg position. The greatest increase in diameter was observed in the Trendelenburg position with the Valsalva manoeuvre (p < 0.001). CONCLUSION In paediatric patients, the application of the Trendelenburg position with the Valsalva manoeuvre gave the greatest increase in RIJV diameter. The reverse Trendelenburg position had no significant effect on RIJV diameter.
dc.identifier.citationDinçyürek, G. N. vd. (2015). ''The effects of the Trendelenburg position and the valsalva manoeuvre on internal jugular vein diameter and placement in children''. Singapore Medical Journal, 56(8), 468-471.
dc.identifier.doihttps://doi.org/10.11622/smedj.2015020
dc.identifier.endpage471
dc.identifier.issn0037-5675
dc.identifier.issue8
dc.identifier.pubmed25597750
dc.identifier.scopus2-s2.0-84939483161
dc.identifier.startpage468
dc.identifier.urihttp://www.smj.org.sg/article/effects-trendelenburg-position-and-valsalva-manoeuvre-internal-jugular-vein-diameter-and
dc.identifier.urihttps://hdl.handle.net/11452/39530
dc.identifier.volume56
dc.identifier.wos000359724700013
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherSingapore Medical Association
dc.relation.journalSingapore Medical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCatheterisation
dc.subjectReverse Trendelenburg
dc.subjectTrendelenburg
dc.subjectUltrasonography
dc.subjectValsalva
dc.subjectCentral venous cannulation
dc.subjectCross-sectional area
dc.subjectDifficult intravenous access
dc.subjectUltrasound guidance
dc.subjectHead rotation
dc.subjectIntrathoracic pressure
dc.subjectCatheter placement
dc.subjectPediatric-patients
dc.subjectYoung-children
dc.subjectFemoral vein
dc.subjectGeneral & internal medicine
dc.subject.emtreeSevoflurane
dc.subject.emtreeEther derivative
dc.subject.emtreePropofol
dc.subject.emtreeArticle
dc.subject.emtreeBody position
dc.subject.emtreeCarotid artery injury
dc.subject.emtreeCatheterization
dc.subject.emtreeChild
dc.subject.emtreeEchography
dc.subject.emtreeEnd tidal carbon dioxide tension
dc.subject.emtreeFemale
dc.subject.emtreeHuman
dc.subject.emtreeJugular vein
dc.subject.emtreeMajor clinical study
dc.subject.emtreeMale
dc.subject.emtreePatient information
dc.subject.emtreeProspective study
dc.subject.emtreeSupine position
dc.subject.emtreeTrendelenburg position
dc.subject.emtreeValsalva maneuver
dc.subject.emtreeAnatomy and histology
dc.subject.emtreeAnesthesia
dc.subject.emtreeBody posture
dc.subject.emtreeDiagnostic imaging
dc.subject.emtreePreschool child
dc.subject.emtreeProcedures
dc.subject.emtreeSupine position
dc.subject.meshValsalva maneuver
dc.subject.meshAnesthesia
dc.subject.meshChild
dc.subject.meshChild, preschool
dc.subject.meshFemale
dc.subject.meshHead-down tilt
dc.subject.meshHumans
dc.subject.meshJugular veins
dc.subject.meshMale
dc.subject.meshMethyl ethers
dc.subject.meshPropofol
dc.subject.meshSupine position
dc.subject.meshUltrasonography
dc.subject.scopusCentral Venous Catheterization; Catheterization; Catheters
dc.subject.wosMedicine, general & internal
dc.titleThe effects of the Trendelenburg position and the valsalva manoeuvre on internal jugular vein diameter and placement in children
dc.typeArticle
dc.wos.quartileQ4 (Medicine, general & internal)
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Anesteziyoloji Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus

Files

Original bundle

Now showing 1 - 1 of 1
Placeholder
Name:
Dinçyürek_vd_2015.pdf.crdownload
Size:
163.95 KB
Format:
Unknown data format

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: