Publication:
Performance analysis of a re-circulating heat pump dryer

dc.contributor.buuauthorYamankaradeniz, Nurettin
dc.contributor.buuauthorSökmen, K. Furkan
dc.contributor.buuauthorCoşkun, Salih
dc.contributor.buuauthorKaynaklı, Ömer
dc.contributor.buuauthorPastakkaya, Bilsay
dc.contributor.departmentOrhangazi Meslek Yüksekokulu
dc.contributor.departmentTeknik Bilimler Meslek Yüksekokulu
dc.contributor.departmentMühendislik ve Mimarlık Fakültesi
dc.contributor.departmentFen Bilimleri Enstitüsü
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.departmentMakine Mühendisliği Bölümü
dc.contributor.departmentElektrik ve Enerji Bölümü
dc.contributor.orcid0000-0001-8647-4861
dc.contributor.orcid0000-0001-5027-9458
dc.contributor.researcheridR-5685-2016
dc.contributor.researcheridAAA-1753-2021
dc.contributor.researcheridR-2401-2018
dc.contributor.scopusid26645227400
dc.contributor.scopusid26645227400
dc.contributor.scopusid26644674500
dc.contributor.scopusid8387145900
dc.contributor.scopusid56257775400
dc.date.accessioned2022-12-14T13:22:51Z
dc.date.available2022-12-14T13:22:51Z
dc.date.issued2014-06-08
dc.description.abstractA re-circulating heat pump dryer (HPD) system was designed, constructed and tested at steady-state and transient conditions. Refrigerant 134a was used as a refrigerant in this system. The tests were performed to observe behavior of HPD system. So, changes of temperature and relative humidity of drying air through the dryer and heat pump operating temperatures were observed during the drying process and effects of by-pass air ratio (BAR) on the system's parameters as system performance and specific moisture extracted ratio (SMER) at steady-state were investigated. The HPD system was also tested to investigate temperatures and relative humidity changes of drying air during drying process on the system's parameters depend on time. Airflow rate circulated through the HPD system was 554 m(3)/h during the all tests. According to test results, the system's parameters did not change up to 40% of BAR. Then the coefficient at performance (COP) and SMER values were decreased after 40% of BAR. While SMER values changed between 1.2 and 1.4, COPsys changed between 2.8 and 3.3 depend on BAR. As well as during the drying process, the COP and SMER values were also affected and decreased depend on time.
dc.identifier.citationYamankaradeniz, N. vd. (2016). "Performance analysis of a re-circulating heat pump dryer". Thermal Science, 20(1), 267-277.
dc.identifier.endpage277
dc.identifier.issn0354-9836
dc.identifier.issn2334-7163
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84963620299
dc.identifier.startpage267
dc.identifier.urihttps://doi.org/10.2298/TSCI130426069Y
dc.identifier.urihttp://www.doiserbia.nb.rs/Article.aspx?ID=0354-98361400069Y#.Y4DHQn1ByM8
dc.identifier.urihttp://hdl.handle.net/11452/29887
dc.identifier.volume20
dc.identifier.wos000373314400025
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherVinca Inst Nuclear
dc.relation.bapM-2008/63
dc.relation.journalThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectThermodynamics
dc.subjectDrying
dc.subjectDryer
dc.subjectHeat pump
dc.subjectBy-pass air ratio
dc.subjectHeat pump assisted dryer
dc.subjectSimulation-model
dc.subjectSystem
dc.subjectDryers (equipment)
dc.subjectHeat pump systems
dc.subjectPumps
dc.subjectRefrigerants
dc.subject%moisture
dc.subjectAir ratio
dc.subjectBy pass
dc.subjectBy-pass air ratio
dc.subjectDrying process
dc.subjectHeat pump dryer system
dc.subjectHeat pumps
dc.subjectSystems parameters
dc.subject.scopusDrying Apparatus; Drying; Exergy
dc.subject.wosThermodynamics
dc.titlePerformance analysis of a re-circulating heat pump dryer
dc.typeArticle
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentTeknik Bilimler Meslek Yüksekokulu/Elektrik ve Enerji Bölümü
local.contributor.departmentMühendislik ve Mimarlık Fakültesi/Makine Mühendisliği Bölümü
local.contributor.departmentOrhangazi Meslek Yüksekokulu
local.contributor.departmentFen Bilimleri Enstitüsü/Makine Mühendisliği Bölümü
local.indexed.atScopus
local.indexed.atWOS

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Yamankaradeniz_vd_2016.pdf
Size:
269.92 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: