Effect of zero air change rate on particle dispersion in a room with floor heating

dc.contributor.authorMutlu M.
dc.contributor.buuauthorMUTLU, MUSTAFA
dc.contributor.departmentYenişehir İbrahim Orhan Meslek Yüksekokulu
dc.contributor.orcid56998409300
dc.date.accessioned2025-05-13T09:28:26Z
dc.date.issued2019-08-13
dc.description.abstractDispersion of airborne particles in the office and residential areas should be well known as these particles in an enclosed volume has a significant effect on human health. In this study, the effect of the floor heating system, which is often preferred by end users due to the energy efficiency of low heating systems, on particle distribution in a room was investigated numerically. It is essential to examine the floor heating having a significant place among low heating systems, concerning particle dispersion. In enclose volumes, ambient air should be replaced with fresh air that is supplied from outdoor in order to ensure indoor air quality. However, the ideal air change rates may not be met for daily use, even in some cases air change rates might be zero. Therefore, in this study absence of air change were assumed, and after temperature and velocity distributions were determined, five different sized particles were tracked by using Eulerian-Lagrangian model. Additionally, three heating capacities (35 W/m2 41.25 W/m2 and 47 W/m2) of the floor heating system were investigated. In this study, where computational fluid dynamics were used, the effect of drag, lift, thermophoretic and Brownian forces were considered. It was found that particles were settled on walls and ceiling due to zero air change rate, and particle concentration rises in the lower part of the wall as particle diameter increases.
dc.identifier.doi10.1051/e3sconf/201911102037
dc.identifier.issn2555-0403
dc.identifier.scopus2-s2.0-85071890733
dc.identifier.urihttps://hdl.handle.net/11452/52101
dc.identifier.volume111
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherEDP Sciences
dc.relation.journalE3S Web of Conferences
dc.relation.tubitak118M222
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.scopusCooling System; Floors; Thermal Comfort
dc.titleEffect of zero air change rate on particle dispersion in a room with floor heating
dc.typeConference Paper
dspace.entity.typePublication
relation.isAuthorOfPublication7bde71fb-a52b-43a8-adbb-df86c8b51ce7
relation.isAuthorOfPublication.latestForDiscovery7bde71fb-a52b-43a8-adbb-df86c8b51ce7

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Mutlu_2019.pdf
Size:
2.46 MB
Format:
Adobe Portable Document Format

Collections