Abstract

This work presents the concept of the PICOSEC-Micromegas detector to achieve a time resolution below 30 ps. PICOSEC consists of a two-stage Micromegas detector coupled to a Cherenkov radiator and equipped with a photo-cathode. The results from single-channel prototypes as well as the understanding of the detector in terms of detailed simulations and preliminary results from a multichannel prototype are presented.

Description

Bu çalışma, 03-05 Eylül 2019 tarihleri arasında Acireale[İtalya]’da düzenlenen International Workshop on Fast Timing Applications for Nuclear Physics and Medical Imaging (FATA)’da bildiri olarak sunulmuştur.