Publication:
Low-power laser treatment for shoulder pain

dc.contributor.buuauthorBingöl, Ümit
dc.contributor.buuauthorAltan, Lale
dc.contributor.buuauthorYurtkuran, Merih
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentRomatizmal Hastalıklar ve Hidroterapi Ana Bilim Dalı
dc.contributor.researcheridAAH-1652-2021
dc.date.accessioned2021-07-05T08:33:53Z
dc.date.available2021-07-05T08:33:53Z
dc.date.issued2005-10
dc.description.abstractObjective: The objective of this study is to investigate the effect of low-power gallium-arsenide laser treatment on the patients with shoulder pain. Backround Data: Low-energy laser therapy has recently been popularized in the treatment of various rheumatologic, neurologic, and musculoskeletal disorders such as osteoarthritis, rheumatoid arthritis, fibromyalgia, carpal tunnel syndrome, rotator cuff tendinitis, and chronic back pain syndromes. Methods: A total of 40 patients who applied to our clinic with shoulder pain and complied with the selection criteria were included in the study. The patients were randomly assigned into Group I (n = 20, laser treatment) and Group II (n = 20, control). In Group I, patients were given laser treatment and an exercise protocol for 10 sessions during a period of 2 weeks. Laser was applied over tuberculum majus and minus, bicipital groove, and anterior and posterior faces of the capsule, regardless of the existence of sensitivity, for 1 min at each location at each session with a frequency of 2000 Hz using a GaAs diode laser instrument (Roland Serie Elettronica Pagani, wavelength 904 nm, frequency range of 5-7000 Hz, and maximum peak power of 27 W, 50 W, or 27 X 4 W). In Group II, placebo laser and the same exercise protocol was given for the same period. Patients were evaluated according to the parameters of pain, palpation sensitivity, algometric sensitivity, and shoulder joint range of motion before and after treatment. Results: Analysis of measurement results within each group showed a significant posttreatment improvement for some active and passive movements in both groups, and also for algometric sensitivity in Group I (p < 0.05-0.01). Posttreatment palpation sensitivity values showed improvement in 17 patients (85%) for Group I and six patients (30%) for Group II. Comparison between two groups showed superior results (p < 0.01 and p < 0.001) in Group I for the parameters of passive extension and palpation sensitivity but no significant difference for other parameters. Conclusions: The results of our study have shown better results in palpation sensitivity and passive extension, but no significant improvement in pain, active range, and algometric sensitivity in laser treatment group compared to the control group in the patients with shoulder pain.
dc.identifier.citationBingöl, Ü. vd. (2005). "Low-power laser treatment for shoulder pain". Photomedicine and Laser Surgery, 23(5), 459-464.
dc.identifier.endpage464
dc.identifier.issn1549-5418
dc.identifier.issue5
dc.identifier.pubmed16262574
dc.identifier.scopus2-s2.0-27744555637
dc.identifier.startpage459
dc.identifier.urihttps://doi.org/10.1089/pho.2005.23.459
dc.identifier.urihttps://www.liebertpub.com/doi/10.1089/pho.2005.23.459
dc.identifier.urihttp://hdl.handle.net/11452/21049
dc.identifier.volume23
dc.identifier.wos000233178900003
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherMary Ann Liebert
dc.relation.journalPhotomedicine and Laser Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSurgery
dc.subjectLow-level laser
dc.subjectDisorders
dc.subjectDouble-blind
dc.subjectControlled-trial
dc.subjectCorticosteroid injection
dc.subjectGeneral-practice
dc.subjectTherapy
dc.subjectEfficacy
dc.subjectIrradiation
dc.subject.wosSurgery
dc.titleLow-power laser treatment for shoulder pain
dc.typeArticle
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Romatizmal Hastalıklar ve Hidroterapi Ana Bilim Dalı
local.indexed.atWOS
local.indexed.atScopus

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: