Publication:
Effects of immobilization beds on the dose in the entrance and exit dose region for Co-60, 4, 6 and 15 MV photons

dc.contributor.authorBecerir, Hatice Bilge
dc.contributor.authorKüçücük, Halil
dc.contributor.authorÇakır, Aydın
dc.contributor.authorMeral, Rasim
dc.contributor.buuauthorYöndem, Serpil
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentOnkoloji Ana Bilim Dalı
dc.contributor.scopusid25229527800
dc.date.accessioned2024-02-27T12:58:15Z
dc.date.available2024-02-27T12:58:15Z
dc.date.issued2008
dc.description.abstractPurpose: The aim of this study was to determine the effects of Styrofoam beds used for immobilization on build-up and exit dose regions for high energy photon beams. Materials and methods: Build-up dose and exit dose measurements in central axis of Co-60 and 4, 6 and 15 MV photons at various field sizes and source to phantom distances were made in a water equivalent solid phantom with 2, 5 and 10 cm thick uniform Styrofoam beds at the surface. A Markus type plane-parallel ion chamber with fixed separation between collecting electrodes was used to measure the percent depth doses. Results: The surface dose increased almost linearly with field size for Co-60, 4, 6 and 15 MV X-ray beams. The effect of immobilization (Styrofoam beds) on the surface dose increased with the thickness and this effect was lower with higher energies. When a 2 cm thick Styrofoam bed was used for immobilization, the surface dose in a 10 x 10 cm field was higher (43.9, 36.8, 28.8 and 14.9% for Co-60, 4, 6 and 15 MV, respectively). Conclusion: As the Styrofoam bed was thicker, the maximum dose point moved closer to the surface of the phantom for all energies. The exit surface dose was also enhanced with the presence of Styrofoam beds and similar to the effects on the surface dose. This enhancement was the maximum 5% for high energy photon beams and 6% for Co-60 beam. The introduction of Syrofoam beds in the radiation beam for the immobilization of the patient increases surface and exit doses to a considerable extent.
dc.identifier.citationBilge, H. vd. (2008). "Effects of immobilization beds on the dose in the entrance and exit dose region for Co-60, 4, 6 and 15 MV photons". Journal of BUON, 13(3), 385-390.
dc.identifier.endpage390
dc.identifier.issn1107-0625
dc.identifier.issn2241-6293
dc.identifier.issue3
dc.identifier.pubmed18979554
dc.identifier.scopus2-s2.0-53849148972
dc.identifier.startpage385
dc.identifier.urihttps://hdl.handle.net/11452/40012
dc.identifier.volume13
dc.identifier.wos000259689200011
dc.indexed.scopusScopus
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherImprimatur Publication
dc.relation.collaborationYurt içi
dc.relation.collaborationSanayi
dc.relation.journalJournal of BUON
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectOncology
dc.subjectBuild-up dose
dc.subjectExit dose
dc.subjectImmobilization device
dc.subjectRadiotherapy
dc.subjectSurface dose
dc.subjectBuildup region
dc.subjectContamination
dc.subjectBeams
dc.subject.emtreeArticle
dc.subject.emtreeEquipment design
dc.subject.emtreeHospital bed
dc.subject.emtreeImmobilization
dc.subject.emtreePhoton
dc.subject.emtreeRadiation beam
dc.subject.emtreeRadiation depth dose
dc.subject.emtreeRadiation dose
dc.subject.emtreeRadiation dose distribution
dc.subject.emtreeRadiation field
dc.subject.emtreeRadiotherapy
dc.subject.emtreeStyrofoam bed
dc.subject.emtreeThickness
dc.subject.meshBeds
dc.subject.meshCobalt radioisotopes
dc.subject.meshDose-response relationship, radiation
dc.subject.meshHumans
dc.subject.meshPhantoms, imaging
dc.subject.meshPhotons
dc.subject.meshPolystyrenes
dc.subject.meshRadiation dosage
dc.subject.meshRadiation protection
dc.subject.meshRadiotherapy dosage
dc.subject.meshRadiotherapy, high-energy
dc.subject.scopusDose; Couches; Intensity Modulated Radiation Therapy
dc.subject.wosOncology
dc.titleEffects of immobilization beds on the dose in the entrance and exit dose region for Co-60, 4, 6 and 15 MV photons
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Onkoloji Ana Bilim Dalı
local.indexed.atPubMed
local.indexed.atScopus

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: