Effects of intensive care unit noise on patients: A study on coronary artery bypass graft surgery patients

dc.contributor.authorKaymakçı, Şenay
dc.contributor.buuauthorAkansel, Neriman
dc.contributor.departmentUludağ Üniversitesi/Sağlık Yüksekokulu/Hemşirelik Bölümü.tr_TR
dc.contributor.scopusid12797756400tr_TR
dc.date.accessioned2021-11-29T08:19:09Z
dc.date.available2021-11-29T08:19:09Z
dc.date.issued2008-06
dc.description.abstractAims and objectives. The aim of this study was to measure the noise levels in specific locations of an intensive care unit and determine the disturbance levels of patients owing to noise. Background. Studies have shown that hospital noise is a potential stressor for patients. Noise levels measured in the intensive care unit are mostly far beyond the recommended standards for hospitals, and generally measured around 60-70 dB (A). Although there are a few studies on noise levels in the intensive care unit, no study could be found that compares 24-hour intensive care unit noise measurement data at several locations of intensive care unit. Methods. The study was conducted with 35 coronary artery bypass graft surgery patients. The intensive care unit noise level was measured by using Bruel & Kjaer 2144 Model Frequency Analyzer next to the bed of each patient. A patient's disturbance owing to the intensive care unit noise was questioned. Results. Noise levels ranged between 49 and 89 dB (A) with a mean of 65 dB (A). Peak noise levels were measured as high as 89 dB (A). The noise levels measured at different locations in the intensive care unit did not differ significantly. Noises created by other patients, those who were admitted from emergency room and operating room into intensive care unit, monitor alarms, conversations among staff were the most disturbing noise sources for patients. Conclusion. The patients who were located in the bed which was closer to the nurses' station were more affected by the intensive care unit noise than other patients. Having a previous intensive care unit experience also affected the patients' disturbance levels owing to noise. Relevance to clinical practice. Nurses are in key positions where they can identify physical, psychological and social stressors that affect patients during their hospital stay. Staff education, planned nursing activities and proper design of intensive care unit may help combat this overlooked problem.tr_TR
dc.identifier.citationAkansel, N. ve Kaymakçı, S. (2008). ''Effects of intensive care unit noise on patients: A study on coronary artery bypass graft surgery patients''. Journal of Clinical Nursing, 17(12), 1581-1590.tr_TR
dc.identifier.endpage1590tr_TR
dc.identifier.issn0962-1067
dc.identifier.issn1365-2702
dc.identifier.issue12tr_TR
dc.identifier.pubmed18482120tr_TR
dc.identifier.scopus2-s2.0-43849084215tr_TR
dc.identifier.startpage1581tr_TR
dc.identifier.urihttps://doi.org/10.1111/j.1365-2702.2007.02144.x
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/10.1111/j.1365-2702.2007.02144.x
dc.identifier.urihttp://hdl.handle.net/11452/22849
dc.identifier.volume17tr_TR
dc.identifier.wos000255837100006tr_TR
dc.indexed.pubmedPubmedtr_TR
dc.indexed.scopusScopustr_TR
dc.indexed.wosSCIEtr_TR
dc.indexed.wosSSCItr_TR
dc.language.isoentr_TR
dc.publisherWileytr_TR
dc.relation.collaborationYurt içitr_TR
dc.relation.journalJournal of Clinical Nursingtr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/closedAccesstr_TR
dc.subjectNursingtr_TR
dc.subjectDecibeltr_TR
dc.subjectDisturbancetr_TR
dc.subjectIntensive care unittr_TR
dc.subjectNoisetr_TR
dc.subjectNursestr_TR
dc.subjectPatienttr_TR
dc.subjectHospital noisetr_TR
dc.subjectInduced stresstr_TR
dc.subjectCommunicationtr_TR
dc.subjectInterventiontr_TR
dc.subjectSperceptionstr_TR
dc.subjectPollutiontr_TR
dc.subjectAreatr_TR
dc.subject.emtreeAnalysis of variancetr_TR
dc.subject.emtreeArticletr_TR
dc.subject.emtreeAttitude to healthtr_TR
dc.subject.emtreeClinical nursing researchtr_TR
dc.subject.emtreeCoronary artery bypass grafttr_TR
dc.subject.emtreeCross-sectional studytr_TR
dc.subject.emtreeEnvironmental exposuretr_TR
dc.subject.emtreeEnvironmental monitoringtr_TR
dc.subject.emtreeFemaletr_TR
dc.subject.emtreeFurnituretr_TR
dc.subject.emtreehealth care facilitytr_TR
dc.subject.emtreeHumantr_TR
dc.subject.emtreeIntensive caretr_TR
dc.subject.emtreeIntensive care unittr_TR
dc.subject.emtreeMaletr_TR
dc.subject.emtreeMiddle agedtr_TR
dc.subject.emtreeNoisetr_TR
dc.subject.emtreeNonparametric testtr_TR
dc.subject.emtreeNurse attitudetr_TR
dc.subject.emtreeNursing methodology researchtr_TR
dc.subject.emtreeOrganization and managementtr_TR
dc.subject.emtreePsychological aspecttr_TR
dc.subject.emtreeQuestionnairetr_TR
dc.subject.emtreeSound detectiontr_TR
dc.subject.meshAnalysis of variancetr_TR
dc.subject.meshAttitude to healthtr_TR
dc.subject.meshClinical nursing researchtr_TR
dc.subject.meshCoronary artery bypasstr_TR
dc.subject.meshCross-sectional studiestr_TR
dc.subject.meshEnvironmental exposuretr_TR
dc.subject.meshEnvironmental monitoringtr_TR
dc.subject.meshFemaletr_TR
dc.subject.meshHealth facility environmenttr_TR
dc.subject.meshHumanstr_TR
dc.subject.meshIntensive ccare;tr_TR
dc.subject.meshIntensive care unitstr_TR
dc.subject.meshInterior design and furnishingstr_TR
dc.subject.meshMaletr_TR
dc.subject.meshMiddle agedtr_TR
dc.subject.meshNurse's roletr_TR
dc.subject.meshNursing methodology researchtr_TR
dc.subject.meshQuestionnairestr_TR
dc.subject.meshSound spectrographytr_TR
dc.subject.meshStatisticstr_TR
dc.subject.meshNonparametrictr_TR
dc.subject.scopusHearing Protectors; Intensive Care Units; Slow Wave Sleeptr_TR
dc.subject.wosNursingtr_TR
dc.titleEffects of intensive care unit noise on patients: A study on coronary artery bypass graft surgery patientstr_TR
dc.typeArticle
dc.wos.quartileQ1tr_TR

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections