The effect of anterior chamber maintainer on anterior chamber contamination

dc.contributor.buuauthorBaykara, Mehmet
dc.contributor.buuauthorÖzakın, Cüneyt
dc.contributor.buuauthorDoğru, Murat
dc.contributor.buuauthorErtürk, Haluk
dc.contributor.buuauthorHeper, Yasemin
dc.contributor.buuauthorÖzçetin, Hikmet
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı.tr_TR
dc.contributor.researcheridABI-7051-2020tr_TR
dc.contributor.researcheridAAH-6506-2021tr_TR
dc.contributor.scopusid23093006700tr_TR
dc.contributor.scopusid57200678942tr_TR
dc.contributor.scopusid7006540932tr_TR
dc.contributor.scopusid7003716972tr_TR
dc.contributor.scopusid56191003300tr_TR
dc.contributor.scopusid6603402155tr_TR
dc.date.accessioned2023-03-06T07:50:07Z
dc.date.available2023-03-06T07:50:07Z
dc.date.issued2003
dc.description.abstractPURPOSE. To evaluate the effect of anterior chamber continuous infusion maintainer system on the contamination of anterior chamber in phacoemulsification surgery. METHODS. Clear corneal phacoemulsification surgery was performed in 132 eyes of 132 randomly selected patients with cataract who were divided into two groups of 66 eyes according to the use of an anterior chamber maintainer (ACM) system. The fluid specimens were taken from anterior chamber in the beginning and at the end of the surgery. They were transferred under anaerobic conditions and investigated by culturing onto blood agar and thiogluconate broth media. Differences between the two groups with respect to contamination of the specimens were investigated. RESULTS. The mean age of the group undergoing surgery without a maintainer system (Group A) was 63 +/- 10 years (min = 41, max = 80) versus 59 +/- 10 years (min = 33, max = 80) in the other group (Group B) in which the maintainer was used during surgery. In the postoperative specimen, Micrococcus species were isolated from one eye (1.5%) in Group A and S. pyogenes in one eye (1.5%) from Group B. Mean follow-up interval was 12 +/- 6 (min = 4, max 28) months. CONCLUSIONS. The use of ACM system in clear corneal phacoemulsification surgery carries no additional risks as far as contamination is concerned.en_US
dc.identifier.citationBaykara, M. vd. (2003). “The effect of anterior chamber maintainer on anterior chamber contamination”. European Journal of Ophthalmology, 13(9-10), 770-772.en_US
dc.identifier.endpage772tr_TR
dc.identifier.issn1120-6721
dc.identifier.issue9-10tr_TR
dc.identifier.pubmed14700097tr_TR
dc.identifier.scopus2-s2.0-1042290360tr_TR
dc.identifier.startpage770tr_TR
dc.identifier.urihttps://doi.org/10.1177/1120672103013009-1006
dc.identifier.urihttps://journals.sagepub.com/doi/10.1177/1120672103013009-1006
dc.identifier.urihttp://hdl.handle.net/11452/31357
dc.identifier.volume13tr_TR
dc.identifier.wos000187428400006tr_TR
dc.indexed.pubmedPubMeden_US
dc.indexed.scopusScopusen_US
dc.indexed.wosSCIEen_US
dc.language.isoenen_US
dc.publisherSage Publicationsen_US
dc.relation.journalEuropean Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOphthalmologyen_US
dc.subjectPhacoemulsificationen_US
dc.subjectAnterior chamber contaminationen_US
dc.subjectAnterior chamber maintaineren_US
dc.subjectCataract-surgeryen_US
dc.subjectSurgical techniqueen_US
dc.subject.emtreeAdulten_US
dc.subject.emtreeAgeden_US
dc.subject.emtreeAnterior chamber maintaineren_US
dc.subject.emtreeAnterior eye chamber diseaseen_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeClinical trialen_US
dc.subject.emtreeContaminationen_US
dc.subject.emtreeContinuous infusionen_US
dc.subject.emtreeControlled clinical trialen_US
dc.subject.emtreeControlled studyen_US
dc.subject.emtreeCulture mediumen_US
dc.subject.emtreeFemaleen_US
dc.subject.emtreeFollow upen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeMajor clinical studyen_US
dc.subject.emtreeMaleen_US
dc.subject.emtreeMicrococcusen_US
dc.subject.emtreePhacoemulsificationen_US
dc.subject.emtreePriority journalen_US
dc.subject.emtreeAgaren_US
dc.subject.emtreeRandomized controlled trialen_US
dc.subject.emtreeSurgical techniqueen_US
dc.subject.scopusEndophthalmitis; Anti-Bacterial Agents; Cefuroximeen_US
dc.subject.wosOphthalmologyen_US
dc.titleThe effect of anterior chamber maintainer on anterior chamber contaminationen_US
dc.typeArticle
dc.wos.quartileQ4en_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: