Cuffed oropharyngeal airway as a suitable alternative to the laryngeal mask airway for minor outpatient surgery

dc.contributor.authorAcar, H. Volkan
dc.contributor.buuauthorYavaşçaoğlu, Belgin
dc.contributor.buuauthorKahveci, Ferda
dc.contributor.buuauthorKaya, Fatmanur Nazlı Dinçer
dc.contributor.buuauthorÖzcan, Bahar
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Anesteziyoloji Anabilim Dalı.tr_TR
dc.contributor.researcheridAAI-7914-2021tr_TR
dc.contributor.researcheridAAG-9356-2021tr_TR
dc.contributor.researcheridAAI-8213-2021tr_TR
dc.contributor.scopusid6602742300tr_TR
dc.contributor.scopusid6602405968tr_TR
dc.contributor.scopusid7003619647tr_TR
dc.contributor.scopusid6603825848tr_TR
dc.date.accessioned2022-02-25T06:39:51Z
dc.date.available2022-02-25T06:39:51Z
dc.date.issued2002-03
dc.description.abstractBackground and objective: To compare the application of the cuffed oropharyngeal airway and the laryngeal mask airway on anaesthetized adult patients undergoing minor outpatient surgery. Methods: One hundred patients received intravenous fentanyl, propofol and N2O for the induction and maintenance of anaesthesia. The patients were randomly divided into two groups: a cuffed oropharyngeal airway group (n = 50) and a laryngeal mask airway group (n = 50). After insertion of the device, fibreoptic laryngoscopy was attempted and the degree of success scored. We then compared the first application success rate of both procedures while judging airway intervention requirement, fibreoptic scores, adverse airway events and haemodynamic tolerance. Results: Both devices had an almost similar first-time placement rate (cuffed oropharyngeal airway 84% versus laryngeal mask airway 96%). The cuffed oropharyngeal airway required a higher number of airway interventions (P < 0.001). The laryngeal mask airway had a significantly better fibreoptic view compared with the cuffed oropharyngeal airway (P < 0.001). However, the number of adverse airway events was lower in the cuffed oropharyngeal airway group; there were no significant differences in adverse events and haemodynamic variables between the said two groups. Conclusions: The results suggest that the cuffed oropharyngeal airway was an effective alternative airway in spontaneously breathing patients during short procedures.en_US
dc.identifier.citationYavaşçaoğlu, B. vd. (2002). "Cuffed oropharyngeal airway as a suitable alternative to the laryngeal mask airway for minor outpatient surgery". European Journal of Anaesthesiology, 19(3),203-207.en_US
dc.identifier.endpage207tr_TR
dc.identifier.issn0265-0215
dc.identifier.issue3tr_TR
dc.identifier.pubmed12071241tr_TR
dc.identifier.scopus2-s2.0-0036519955tr_TR
dc.identifier.startpage203tr_TR
dc.identifier.urihttps://doi.org/10.1017/S0265021502000364
dc.identifier.urihttps://www.cambridge.org/core/journals/european-journal-of-anaesthesiology/article/abs/cuffed-oropharyngeal-airway-as-a-suitable-alternative-to-the-laryngeal-mask-airway-for-minor-outpatient-surgery/6316B82DA8D6917AEA16CDFB02A167FD
dc.identifier.urihttp://hdl.handle.net/11452/24641
dc.identifier.volume19tr_TR
dc.identifier.wos000174709600009tr_TR
dc.indexed.pubmedPubmeden_US
dc.indexed.scopusScopusen_US
dc.indexed.wosSCIEen_US
dc.language.isoenen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.collaborationSanayitr_TR
dc.relation.journalEuropean Journal of Anaesthesiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCuffed oropharyngeal airwayen_US
dc.subjectIntratrachealen_US
dc.subjectIntubationen_US
dc.subjectLaryngeal mask airwayen_US
dc.subjectCopaen_US
dc.subjectAnesthesiaen_US
dc.subjectManagementen_US
dc.subjectAdjuncten_US
dc.subject.emtreeAnesthesia complicationen_US
dc.subject.emtreeFentanylen_US
dc.subject.emtreeNitrous oxideen_US
dc.subject.emtreeOxygenen_US
dc.subject.emtreePropofolen_US
dc.subject.emtreeAdulten_US
dc.subject.emtreeAmbulatory surgeryen_US
dc.subject.emtreeDeviceen_US
dc.subject.emtreeAnesthesia inductionen_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeCuffen_US
dc.subject.emtreeCuffed oropharyngeal airwayen_US
dc.subject.emtreeLaryngoscopyen_US
dc.subject.emtreeDrug induced diseaseen_US
dc.subject.emtreeFiberoscopeen_US
dc.subject.emtreeHemodynamicsen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeIntermethod comparisonen_US
dc.subject.emtreeLaryngeal masken_US
dc.subject.emtreeMajor clinical studyen_US
dc.subject.emtreeMinor surgeryen_US
dc.subject.emtreeOropharynxen_US
dc.subject.emtreeOutpatienten_US
dc.subject.emtreeOutpatient careen_US
dc.subject.emtreeScoring systemen_US
dc.subject.scopusLaryngeal Masks; Intubation; Respiration Controlen_US
dc.subject.wosAnesthesiologyen_US
dc.titleCuffed oropharyngeal airway as a suitable alternative to the laryngeal mask airway for minor outpatient surgeryen_US
dc.typeArticle
dc.wos.quartileQ2en_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: