Publication:
Nonpharmacological aspects of intravitreal dexamethasone implant injections: A Retrospective Study of 3,430 Injections and Complications

dc.contributor.authorKiriştioğlu, Mehmet Ömer
dc.contributor.authorUcan Gündüz, Gamze
dc.contributor.authorAbdullayeva, Nigar
dc.contributor.authorDoğanay, Selim
dc.contributor.authorYalçınbayır, Özgür
dc.contributor.buuauthorKIRIŞTIOĞLU, MEHMET ÖMER
dc.contributor.buuauthorUÇAN GÜNDÜZ, GAMZE
dc.contributor.buuauthorABDULLAYEVA, NIGAR
dc.contributor.buuauthorDOĞANAY, SELİM
dc.contributor.buuauthorYALÇINBAYIR, ÖZGÜR
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentGöz Hastalıkları Ana Bilim Dalı
dc.contributor.orcid0000-0001-8010-0105
dc.contributor.scopusid57944467200
dc.date.accessioned2025-05-12T22:31:17Z
dc.date.issued2025-01-01
dc.description.abstractPurpose:This study aims to evaluate the nonpharmacological safety profile of intravitreal dexamethasone implants in cases with different etiologies.Methods:This retrospective university-based study analyzed clinical reports of patients receiving 0.7 mg dexamethasone implant injections between 2013 and 2023. The study recorded patient demographics, injection indications, and follow-up data. Complications caused by the injection procedure and adverse events other than pharmacological side effects within a 3-month period were included.Results:In this study, 3,430 dexamethasone implant injections were made into 1,471 eyes of 1,091 patients. Nonpharmacological complications developed in 611 injections (17.8%). Subconjunctival hemorrhage was noted as the leading nonpharmacological complication (n = 576, 16.8%). Sight-threatening 35 nonpharmacological adverse events and complications (1.0%) were recorded. Cases of anterior chamber migration, vitreous hemorrhage, retinal detachment, endophthalmitis, hypotony, and implant misplacement were observed. Cases requiring intensive treatments and additional surgical interventions were encountered.Conclusion:The injection of the dexamethasone implant may lead to nonpharmacological complications caused by the mechanical impact of the injection or improper positioning of the implant, potentially resulting in vision loss. Severe outcomes such as corneal decompensation, retinal detachment, and endophthalmitis can ensue, emphasizing the gravity of these complications. Careful selection of patients and adherence to proper injection techniques are essential in reducing these risks.
dc.identifier.doi10.1097/IAE.0000000000004270
dc.identifier.endpage106
dc.identifier.issn0275-004X
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85205516698
dc.identifier.startpage95
dc.identifier.urihttps://hdl.handle.net/11452/51341
dc.identifier.volume45
dc.indexed.scopusScopus
dc.language.isoen
dc.publisherLippincott Williams and Wilkins
dc.relation.journalRetina
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectInjection
dc.subjectImplant
dc.subjectEndophthalmitis
dc.subjectDexamethasone
dc.subjectComplication
dc.subjectAnterior chamber migration
dc.subjectAdverse event
dc.subject.scopusDexamethasone Implants in Ocular Treatments
dc.titleNonpharmacological aspects of intravitreal dexamethasone implant injections: A Retrospective Study of 3,430 Injections and Complications
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Göz Hastalıkları Ana Bilim Dalı
relation.isAuthorOfPublication27205b87-a813-4fee-a1e1-396af3797689
relation.isAuthorOfPublicationfcd16549-6bb4-4c75-9919-689a032002f2
relation.isAuthorOfPublication75b870fe-4d45-46cb-b4f5-c6d0414d5f33
relation.isAuthorOfPublication1ec74e0d-8a28-42f8-be6a-e8f6dd11e958
relation.isAuthorOfPublicatione21cc14e-0a29-42c8-a7a0-93bd3c780b36
relation.isAuthorOfPublication.latestForDiscovery27205b87-a813-4fee-a1e1-396af3797689

Files

Collections