Publication:
Konvansiyonel baş-boyun radyoterapisinde dozimetrik sürecin termolüminisans dozimetre ile kontrolü

dc.contributor.authorYeşil, Abdullah
dc.contributor.authorKaynak, Gökay
dc.contributor.buuauthorAltay, Ali
dc.contributor.buuauthorGözcü, Sema
dc.contributor.buuauthorArslan, Sonay
dc.contributor.buuauthorKaradağ, Oya
dc.contributor.buuauthorÖzkan, Lütfi
dc.contributor.buuauthorDemiröz, Candan
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentNükleer Fizik Ana Bilim Dalı
dc.date.accessioned2021-04-02T12:00:35Z
dc.date.available2021-04-02T12:00:35Z
dc.date.issued2011-07-22
dc.description.abstractBu çalışmada amacımız baş-boyun radyoterapi tekniğinde dozimetrik sürecinin termolüminisans dozimetri (TLD) ile kontrolüdür. Çalışmamızda randofantom, dozimetrik ekipman ve tedavi cihazları kullanıldı. Tedavi pozisyonunda Bilgisayarlı Tomografi-Simülatörde, kesit görüntüler alındı. Sanal simülasyonla alanlar belirlendi. Alınan simülasyon filmleri Bilgisayarlı Tedavi Planlama Sistemine (BTPS) aktarılarak kontrol edildi ve nokta doz değerleri hesaplandı. TLD’ler randofantomda belirlenen noktalara yerleştirildi ve 5’er kez ışınlama yapılarak ölçüm değerlerinin ortalamaları elde edildi. Çalışmada hedef hacim ve kritik organ dozları incelendi. Planlanan ve ölçülen değerler arasında ±%5’in altındaki değerler kabul edilebilir sınırlar içine alındı. Target volümde bulunan 2 noktada BTPS ile hesaplanan doz değerlerinin ortalaması 207 cGy iken, bu noktalarda TLD ile ölçülen dozların ortalaması 203,5 cGy idi. Fark %2’in altındadır. Supraklaviküler alan ile lateral alanların çakışma düzleminde hesaplanan ve ölçülen dozlar arasındaki fark maksimum %3,59 olarak bulundu. Lenf nodu bölgelerinde ölçülen değerlerde maksimum fark %3,59 idi. Çalışmamızda elde edilen sonuçlar, radyoterapi için belirlenen limitler içinde olsa da, bilgisayarlı tedavi planlama algoritmaları, dozimetrik süreç ve tedavi uygulamasının TLD ile yapılan in vivo doz ölçümleriyle kontrolünün, ideal olmasa da yararlı olabileceğini göstermektedir.
dc.description.abstractIn this study, our purpose is to control dosimetric process of head and neck radiotherapy technique with ThermoLuminescence Dosimeters (TLD). Dosimetric equipment, treatment devices and randofantom were used in the study. At treatment position, cross-sectional areas of randophantom screened with Computerized Tomography-Simulator. Radiotherapy fields identified at virtual simulation. Radiographs from simulation transferred to Computerized Treatment Planning System (CTPS) to control the fields and then point doses calculated. TLDs were placed to determined points at the randophantom then irradiation applied for 5 times to get average values of measurement. Target volume and critical organ doses were evaluated. Difference between the CTPS and measured doses lower than ±%5 was taken in the acceptable limit. The mean of measured doses from 2 points at the target volume were 203,5cGy and mean of calculated CTPS doses were 207cGy. The difference was below %2. Maximum difference of measured and calculated doses at supraclavicular and lateral field junction plane is %3,49. At the lymph node regions, which are within planning treatment volume, the maximum difference was %3,59. In this study, even if results were in the acceptable margin, controlling the CTPS algorithm and treatment period with TLD dosimeters is not ideal, but, useful for all levels.
dc.identifier.citationAltay, A. vd. (2011). ''Konvansiyonel baş-boyun radyoterapisinde dozimetrik sürecin termolüminisans dozimetre ile kontrolü''. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 37(3), 117-122.
dc.identifier.endpage122
dc.identifier.issn1300-414X
dc.identifier.issue3
dc.identifier.startpage117
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/421538
dc.identifier.urihttp://hdl.handle.net/11452/18841
dc.identifier.volume37
dc.language.isotr
dc.publisherUludağ Üniversitesi
dc.relation.collaborationYurt içi
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisi / Journal of Uludag University Medical Faculty
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBaĢ-boyun radyoterapisi
dc.subjectTermolüminisans dozimetri (TLD)
dc.subjectBilgisayarlı tedavi planlama sistemi (BTPS)
dc.subjectRando Fantom
dc.subjectThermoLuminescence dosimeter (TLD)
dc.subjectHead and neck radiotherapy
dc.subjectComputerized treatment planning system (CTPS)
dc.subjectRando phantom
dc.titleKonvansiyonel baş-boyun radyoterapisinde dozimetrik sürecin termolüminisans dozimetre ile kontrolü
dc.title.alternativeControl of the dosimetric process at conventional head and neck radiotherapy with thermo luminescence dosimeter
dc.typeArticle
dc.typeAraştırma makalesi
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Radyasyon Onkolojisi Ana Bilim Dalı
local.contributor.departmentFen Edebiyat Fakültesi/Nükleer Fizik Ana Bilim Dalı

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
37_3_3.pdf
Size:
548.37 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: