Publication:
Erken evre meme kanserli hastalarda hızlandırılmış kısmi meme ışınlamasında VMAT-CyberKnife sanal tedavi planlarının incelenmesi

dc.contributor.buuauthorKılıç, Hidayetül Mediha
dc.contributor.buuauthorÇetintaş, Sibel Kahraman
dc.contributor.buuauthorTosun, Mehmet
dc.contributor.buuauthorZorlutuna, Metin
dc.contributor.buuauthorTunç, Sema Gözcü
dc.contributor.buuauthorKurt, Meral
dc.contributor.buuauthorAbakay, Candan Demiröz
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentRadyasyon Onkolojisi Ana Bilim Dalı
dc.contributor.orcid0000-0002-0022-1140
dc.contributor.orcid0000-0002-4483-9284
dc.contributor.orcid0000-0002-8034-2507
dc.contributor.orcid0000-0001-9445-2208
dc.contributor.orcid0000-0003-4697-8234
dc.contributor.orcid0000-0003-1637-910X
dc.contributor.orcid0000-0001-5380-5898
dc.date.accessioned2022-06-28T20:55:39Z
dc.date.available2022-06-28T20:55:39Z
dc.date.issued2021-11-02
dc.description.abstractErken evre meme kanserli hastalarda hızlandırılmış kısmi meme ışınlamasında Volümetrik Ark Terapi (VMAT) ve CyberKnife teknikleri kullanılarak hedef volüm ile kritik organ dozlarının karşılaştırılması amaçlanmıştır. Bu çalışma için radyoterapi almış 10 erken evre meme kanseri tanılı hasta seçilerek, günlük fraksiyon dozu 6 Gy ve toplam doz 30 Gy olacak şekilde VMAT ve CyberKnife (SBRT) sanal planları oluşturuldu. Homojenite indeksi (HI), konformite indeksi (CI), tedavi süresi (s), görünür hedef volümü (GTV) ve kritik organların aldığı doz değerleri karşılaştırıldı. Tedavi planları arasında GTV’nin D max (p=0,002) değeri VMAT tekniği lehine anlamlı fark bulundu. Aynı taraf memenin 30 Gy (V 30) (p=0,013) ve 15 Gy alan (V 15) volüm değerlerinin (p=0,007) CyberKnife tekniğinde daha az doz aldığı görüldü. Karşı memenin Dmax (p=0,218) değeri açısından anlamlı bir fark bulunmamıştır. Sağ meme yerleşimli olgularda kalbin D max (p=0,282) ve 1,5 Gy alan (V1,5 ) volümü için (p=0,548) anlamlı fark bulunmadı. Sol meme yerleşimli olgularda kalbin Dmax (p=0,095) değerinde anlamlı fark görülmedi; ancak kalbin 1,5 Gy alan (V 1,5 ) volüm değerinin (p=0,008) CyberKnife tekniğinde daha düşük olduğu görüldü. Tedavi süresi (s) (p<0,001) VMAT tekniğinde anlamlı olarak az bulunmuştur. Sonuç olarak iki tedavi tekniğinde de hedef volümün istenilen dozu aldığı; ancak özellikle erken evrede oluşabilecek geç kardiyak yan etkilerin azaltılması açısından riskli hastalarda CyberKnife tekniğinin daha üstün olduğu anlaşılmıştır. Teknolojik gelişmeler ışığında erken evre meme kanserli hastalarda Hızlandırılmış Kısmi Meme Işınlamasında (APBI) güncel tedavi yaklaşımı olarak CyberKnife tekniği uygun olgularda değerlendirilebilir.
dc.description.abstractIt is aimed to compare target volume and critical organ doses by using Volumetric Arc Th erapy (VMAT) and CyberKnife techniques in accelerated partial breast irradiation in patients with early stage breast cancer. For this study, 10 patients diagnosed with early stage breast cancer who received radiotherapy were selected. VMAT and CyberKnife (SBRT) virtual plans were created with a daily fraction dose of 6 Gy and a total dose of 30 Gy. H omogeneity index (HI), conformity index (CI), treatment duration (s), gross tumor volume (GTV) and dose values received by critical organs were compared. A significant difference was found between the treatment plans in favor of the VMAT technique in the Dmax (p=0.002) value of GTV. It was observed that 30 Gy (V 30 ) (p=0.013) and 15 Gy (V 15 ) values (p=0.007) of the ipsilat- eral breast received less dose in CyberKnife technique. There was no significant difference in terms of Dmax (p=0.218) of the contralateral breast. No significant difference was found for Dmax (p=0.282) and volume of the heart receiving 1.5 Gy (V 1.5 ) (p=0.548) in cases located in the right breast. There was no significant difference in heart Dmax (p=0.095) in cases located in the left breast; however, the value (p=0.008) of the heart receiving 1.5 Gy (V1.5 ) was found to be lower in the CyberKnife technique. The duration (s) of treatment (p<0.001) was found to be significantly less in the VMAT technique. As a result, in both treatment techniques, the target volume received the desired dose; however, it has been found that the CyberKnife technique is superior in risky patients in terms of reducing late cardiac side effects that may occur especially in the early stage. In the light of technological dev elopments, CyberKnife technique can be evaluated in appropriate cases as a current treatment approach in Accelerated Partial Breast Irradiation (APBI) in patients with early stage breast cancer.
dc.identifier.citationKılıç, H. M. vd. (2021). "Erken evre meme kanserli hastalarda hızlandırılmış kısmi meme ışınlamasında VMAT-CyberKnife sanal tedavi planlarının incelenmesi". Uludağ Üniversitesi Tıp Fakültesi Dergisi, 47(3), 357-364.
dc.identifier.endpage364
dc.identifier.issn1300-414X
dc.identifier.issue3
dc.identifier.startpage357
dc.identifier.urihttps://dergipark.org.tr/tr/pub/uutfd/issue/67374/1002193
dc.identifier.urihttps://doi.org/10.32708/uutfd.1002193
dc.identifier.urihttp://hdl.handle.net/11452/27458
dc.identifier.volume47
dc.language.isotr
dc.publisherBursa Uludağ Üniversitesi
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisi / Journal of Uludag University Medical Faculty
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAPBI
dc.subjectErken evre meme kanseri
dc.subjectVolümetrik ark terapi
dc.subjectCyberKnife, SBRT
dc.subjectVolumetric arc therapy
dc.subjectEarly stage breast cancer
dc.titleErken evre meme kanserli hastalarda hızlandırılmış kısmi meme ışınlamasında VMAT-CyberKnife sanal tedavi planlarının incelenmesi
dc.title.alternativeInvestigation of VMAT-Cyberknife virtual treatment plans in accelerated partial breast irradiation in patients with early stage breast cancer
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Radyasyon Onkolojisi Ana Bilim Dalı

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
47_3_6.pdf
Size:
512.94 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: