Browsing by Author "Yamankaradeniz, Nurettin"
Now showing 1 - 20 of 35
- Results Per Page
- Sort Options
Publication A parametric analysis of the performance of organic rankine cycle with heat recovery exchanger and its statistical evaluation(Turkish Soc Thermal Sciences Technology, 2019-01-01) Bademlioğlu, Ali Hüsnü; Canbolat, Ahmet Serhan; YAMANKARADENİZ, NURETTİN; CANBOLAT, AHMET SERHAN; Yamankaradeniz, Nurettin; Kaynaklı, Ömer; KAYNAKLI, ÖMER; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; AAA-1753-2021; HPH-3328-2023; AAI-8222-2021In this study, the performance of a case study of Organic Rankine Cycle with heat recovery exchanger using different fluids is analyzed. As the fluids worked in the cycle, the commonly used R134a, R236fa, R245fa, R600a, R717 and R718 are preferred. Cycle performances of the selected fluids are compared based on both the heat source's temperature that changes between 80 degrees C and 109 degrees C and the effectiveness of the heat exchanger. Furthermore, the contribution ratios and the order of importance of the parameters affecting the performance of the cycle are evaluated using the Taguchi statistical method. As a result, the effect of the waste-heat source temperature on the performance of the system is greater than the other parameters examined, and the contribution ratio of this parameter is determined as 59.80%. However, effectiveness of heat exchanger is found to be the least effective parameter and the effect ratio is calculated as 2.18%. In addition, the best and worst operating conditions are determined from the statistical analysis, and in these conditions, the thermal efficiencies of the Organic Rankine Cycle are obtained as 15.26% and 8.61%, respectively.Item Çeşitli cihazlar için standart olmayan kalibrasyon metotları ve validasyon çalışmalarının standart metotlarla karşılaştırılması(Bursa Uludağ Üniversitesi, 2019-07-01) Kılıç, İsmail Fırat; Yamankaradeniz, Nurettin; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.Bu tezde, sanayi kuruluşları ve imalat atelyelerinde sıklıkla kullanılan ölçme cihazlarının kalibrasyonlarının yapıldığı referans ölçme cihazlarının, kullanıla gelinen referanslar yerine daha hassas ölçüm sonuçları ve daha düşük ölçüm belirsizlikleri elde edinileceği düşünülen, farklı referans cihazla kalibrasyonlarının yapılması ve daha doğru sonuçlar elde edip, daha düşük ölçüm belirsizlikleri ile kalibrasyonların raporlanması amaçlanmıştır. Çalışmada temel olarak Boyutsal ölçümler için sanayi kuruluşlarınca kullanılan, temel ölçme cihazlarının kalibrasyon işlemlerinde kullanılan referanslardan başlıcaları için yeni kalibrasyon metotları geliştirilmeye çalışılmıştır. Bu referans cihazlar ; Kameralı Ölçüm Cihazı, Universal Uzunluk Ölçüm Cihazı ve Ölçme Saati Kalibratörü olarak değerlendirilmiştir. Boyutsal kalibrasyon alanında kullanılan bu referans cihazlar için bilinen ve kullanılan kalibrasyon metotları dışında referans olarak Lazer İnterferometre yöntemi kullanılmış ve daha az sapma içeren kalibrasyon sonuçları ve daha düşük ölçüm belirsizlikleri elde edilmeye çalışılmıştır.Item Computational thermal analysis of cylindrical fin design parameters and a new methodology for defining fin structure in LED automobile headlamp cooling applications(Elsevier, 2015-10-15) Sökmen, Kemal Furkan; Yürüklü, Emrah; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/İklimlendirme ve Soğutma Programı.; AAA-1753-2021; 26645227400In this study, the effects of fin design, fin material, and free and forced convection on junction temperature in automotive headlamp cooling applications of LED lights are researched by using ANSYS CFX 14 software. Furthermore a new methodology is presented for defining the optimum cylindrical fin structure within the given limits. For measuring the performance of methodology, analyses are carried out for various ambient temperatures (25 degrees C, 50 degrees C and 80 degrees C) and different LED power dissipations (0.5 W, 0.75 W, 1 W and 1.25 W). Then, analyses are repeated at different heat transfer coefficients and different fin materials in order to calculate LED junction temperature in order to see if the fin structure proposed by the methodology is appropriate for staying below the given safety temperature limit. As a result, the suggested method has always proposed proper fin structures with optimum characteristics for given LED designs. As another result, for safe junction temperature ranges, it is seen that for all LED power dissipations, adding aluminum or copper plate behind the printed circuit board at low ambient temperatures is sufficient. Also, as the ambient temperature increases, especially in high powered LED lights, addition of aluminum is not sufficient and fin usage becomes essential. High heat transfer coefficient and using copper fin affect the junction temperature positively.Item The effect of water vapor diffusion resistance factor of insulation materials for outer walls on condensation(Türk Isı Bilimi ve Teknik Derneği, 2018) Bademlioglu, Ali Husnu; Kaynaklı, Ömer; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Mühendislik Fakültesi/Makina Mühendisliği Bölümü.; AAA-1753-2021; 8387145900; 26645227400Condensation, which is the result of water vapor diffusion, affects the heat transfer in the building material negatively. The condensation which is seen mostly in winter seasons at building materials, occurs when the surface temperature of the building material in contact with air falls below the raw temperature of the air. In this case, condensed water may cause mildew, fungal growth, odors, and deterioration of dye and building materials or adversely affected thermal insulation on the walls. Materials used for thermal insulation in buildings constitute resistance against water vapor diffusion. Water vapor diffusion resistance factor (VDRF) of materials can vary over a wide range. In this study, considering VDRF range that is commonly encountered in insulation applications, the effect of VDRF of insulation materials on condensation within constructions, and on the minimum thickness of insulation required to prevent this condensation accordingly were examined. Externally insulated wall was taken as sample wall model, heat and mass transfer calculations from wall unit area and insulation thickness minimization were performed for different indoor outdoor temperatures and relative humidity values. As a result of the analysis conducted, in constant indoor-outdoor conditions in general, as VDRF increases, the risk of condensation inside the wall first decreases and then increases. Minimum insulation thickness that is required to be applied to prevent condensation also shows a similar trend depending on the VDRF. For constant VDRF, it was come to the conclusion that as the difference between indoor outdoor temperatures and relative humidity increases, the risk of condensation and consequently required insulation thickness increases.Item Endüstride ısı pompası kullanılarak atık ısıdan ısı geri kazanımının teorik ve deneysel incelenmesi(Uludağ Üniversitesi, 2011) Yamankaradeniz, Nurettin; Can, Muhiddin; Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.Enerjinin yetersizliği ve var olan kaynakların çevreye olan zararları, enerji konusundaki araştırmaları güncel ve önemli kılmaktadır. Bu nedenle enerji tasarrufu sağlayıcı tekniklerin bulunması, araştırılması ve geliştirilmesi zorunlu hale gelmiştir. Bu kapsamda gelişmiş ülkelerdeki üniversitelerde ve sanayide belirtilen konularda teorik ve deneysel araştırma ve geliştirme çalışmaları sistemli ve planlı bir şekilde sürdürülmektedir. Gelişmiş ülkelerde; ısı pompaları, konfor amaçlı kullanımın yanında, endüstride kurutma işlemlerinde ve atık sıvıdan ısı geri kazanım amaçlı yaygın olarak kullanılmaktadır. Ülkemizde ısı pompalarının konfor amaçlı uygulamaları belli oranda yaygınlaşırken, endüstriyel alanlarda ısı geri kazanımı için ısı pompası uygulamaları oldukça sınırlıdır. Bu nedenle, yapılan bu doktora tezinin amacı, ülkemizde endüstride mevcut atık sıvıların ısısından ve kurutma proseslerinden atılan nemli ve sıcak havadan ısı geri kazanımında, klasik yöntemler yerine ısı pompası kullanımın yaygınlaşmasına katkıda bulunmaktır. Bu amaç doğrultusunda, endüstride enerji tasarrufuna katkı sağlamak amacıyla iki farklı endüstriyel uygulama için iki farklı prototip ısı pompası deney tesisatı tasarlandı ve kuruldu.Birinci çalışmada, endüstride kurutma proseslerinde kurutma odasından ayrılan nemli ve sıcak havanın ısısından ısı geri kazanmak amacıyla kurulan prototip ısı pompası deney tesisatı, iki farklı hava debisi ve farklı by-pass oranları için test edildi. Bu sistemin performansı ve performansına etki eden parametreler ayrı ayrı incelendi. Ayrıca, bu tip uygulamalar için ısı pompası tasarımında dikkat edilmesi gereken parametreler tespit edildi. İkinci çalışmada ise, endüstride bir çok proses sonucu açığa çıkan ve drenaja atılan (30-50 °C) aralığında düşük sıcaklıklarda atık sıvılar mevcuttur. Bu atık sıvıların ısısından yararlanmak amacıyla kurulan prototip ısı pompası deney tesisatı, iki farklı kompresör hızı için, farklı atık sıvı debi ve sıcaklıklarında test edildi. Bu sistemin performansı ve performansa etki eden parametreler incelendi. Ayrıca, bu tip uygulamalar için ısı pompası tasarımında göz önüne alınması gereken parametreler tespit edildi.Her iki çalışma için matematik modelleme geliştirildi ve elde edilen teorik sonuçlar deneysel sonuçlarla karşılaştırıldı. Elde edilen teorik sonuçların deneysel sonuçlar ile uyum içerisinde olduğu tespit edildi. Son olarak, her iki sistem için basit bir ekonomik analiz yapıldı ve elde edilen sonuçlara göre, her iki uygulama için de ısı pompası kullanımının oldukça verimli olduğu görüldü.Item Energy, exergy and thermoeconomic analysis of a natural gas assisted geothermal central heating system(Bursa Uludağ Üniversitesi, 2021-09-24) Yamankaradeniz, Nurettin; Şahmerdan, Orhan; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Bölümü.; 0000-0003-1657-2604; 0000-0001-8129-6808In this work, a natural gas assisted geothermal central heating system in northwestern Turkey utilising low enthalpy geothermal fluid and natural gas as the sources for space heating was analyzed.The study comprised energy, exergy and thermoeconomic analyses of the system under hybrid operating conditions (i.e., from 1 January 2020 to 31 March 2020). The data were collected from a basis of the facility which operates the system. The values about the heat pumps were obtained from the department of the sales company in Istanbul, Turkey and the ‘Average Values for Hybrid Case’ were determined. This work covers energetically, exergetically and thermoeconomically assessment of the system in question through its all stages. The results were found with regard to the system performance investigation. The whole system efficiencies of energy and exergy were found as 56.77% and 49.93% respectively. The exergy cost value per hour and the thermoeconomic factor were calculated as 411.242 €/h and 9.8% respectively.Item Evaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump(Elsevier Science, 2012-06) Motorcu, Ali Rıza; Coşkun, Salih; Yamankaradeniz, Nurettin; Pulat, Erhan; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/Elektrik ve Enerji Bölümü.; Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü.; AAA-1753-2021; 26644674500; 26645227400This paper deals with an investigation of the effect and optimization of control parameters on the system performance in waste heat recovery application using mechanical heat pump (MHP). The experimental studies have been conducted under varying compressor speed, wastewater temperature and flow rate. The experiments have been planned based on Taguchi's L27 orthogonal array with each trial performed under different conditions of compressor's speed, wastewater temperature and flow rate. The optimum parameter combination has been obtained by using the analysis of signal-to-noise (S/N) ratio. The level of importance of the control parameters on the system performance has been determined by using analysis of variance (ANOVA). Main effects plots and interaction effects plots have been utilized to optimize and analyze the relation between the control parameters and the system performance. The results obtained from Taguchi method were also compared with ANN results. The experimental study indicated that it is possible to increase system performance significantly in the waste heat recovery application using MHP.Item Exergoeconomic analysis of a district heating system for geothermal energy using specific exergy cost method(Pergamon-Elsevier Science, 2013-10) Alkan, Mehmet Ali; Keçebaş, Ali; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/İklimlendirme ve Soğutma Teknolojisi Bölümü.; AAA-1753-2021; 26645227400This study presents the exergoeconomic analysis and evaluation in order to provide cost based information and suggests possible locations/components in a GDHS (geothermal district heating system) for improving the cost effectiveness. The analysis is based on the SPECO (specific exergy costing) method, and used to calculate exergy-related parameters and display cost flows for all streams and components. As a real case study, the Afyon GDHS in Turkey is considered based on actual operational data. The obtained results show that the unit exergy cost of heat produced by the Afyon GDHS is calculated as average 5624 $/h. The HEX (heat exchanger)-III among all components should be improved quickly due to the high total operating cost rate and relative cost difference. The HEX-I and PM (pump)-V have the highest exergoeconomic factors among all other system components due to the high owning and operating costs of these components. The heat production costs per exergy unit for all the HEXs decrease due to the high exergy destruction cost rate of the system, while the well head temperature and ambient temperature increase. The SPECO method may be used to improve the cost effectiveness according to exergy rates in GDHSs as a thermal system.Publication Exergy and exergoeconomic analyses of an orc-assisted vapour compression refrigeration cycle(Inderscience Enterprises Ltd, 2022-01-01) Yamankaradeniz, Nurettin; YAMANKARADENİZ, NURETTİN; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.In this study, the thermodynamic performance of a vapour compression refrigeration cycle (VCRC) in which an organic Rankine cycle (ORC) has integrated and that generates electricity by utilising a geothermal source is investigated. The system's energy and exergy performance has evaluated by using various refrigerants used in the ORC system, depending on the evaporator (ORC) temperature (70 degrees C-120 degrees C), and an exergoeconomic analysis has performed to determine optimum operating conditions. As a function of the refrigerant and evaporator temperature, the coefficient of performance (COPsys) of the integrated system has varied between 0.55 and 1.01, whereas the exergy efficiency has varied between 14.20% and 20.16%. The unit exergy cost of the cooled air has been determined as 27.22 USD/GJ under the optimum operating conditions.Item Experimental analysis of a solar absorption system with interior energy storage(University Cape Town, 2012-05) Pastakkaya, Bilsay; Yamankaradeniz, Nurettin; Kaynaklı, Ömer; Coşkun, Salih; Yamanakaradeniz, Recep; Uludağ Üniversitesi/Orhangazi Meslek Yüksekokulu.; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu.; Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; 0000-0001-5027-9458; AAA-1753-2021; R-2401-2018; 56257775400; 26645227400; 8387145900; 26644674500; 56257534000This study examines experimentally the cooling application of a solar absorption system with interior energy storage that uses two different auxiliary systems. The experiments were performed at Uludag University, Bursa, Turkey on the 3rd and 4th of August 2010 that had the approximately same average outdoor temperature, 31 degrees C. A solar hot water was delivered via a 40 m2 array of flat plate solar collectors that drove a lithium chloride (LiCl) absorption heat pump with a cooling power peak of 20 kW A solar-powered air conditioning system was designed for heating and cooling in a test room that had a total floor space of 30 m2. Chilled water produced in the evaporator was supplied to the fan coil units, and the heat of condensation and absorption was rejected by means of a wet cooling tower. An electric heater and an air source heat pump were used as auxiliary systems for the absorption cooling application for two different cases when the solar energy was insufficient. Temperature variations were recorded for the absorption machine components, the test room, and the outdoors. The cooling energy, thermal energy, and daily average coefficient of performance (COP) of the absorption system were calculated for two days. Solar absorption cooling was considered for two different auxiliary systems and is presented in this manuscript. The results showed that the daily average COP of the absorption system was 0.283 for Case 1 and 0.282 for Case 2. For both cases, the interior energy storage of the absorption system enabled it to satisfy the cooling demand during the night while solar energy was not available.Item Experimental study of horizontal ground source heat pump performance for mild climate in Turkey(Pergamon-Elsevier Science, 2009-09) Pulat, Erhan; Çoşkun, Salih; Ünlü, Kürşat; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/İklimlendirme ve Soğutma Programı.; AAK-6963-2021; AAA-1753-2021; 23098080300; 26644674500; 25628645400; 26645227400The aim of this study is to evaluate the performance of horizontal GSHP by considering various system parameters for winter climatic condition of Bursa, Turkey. For this purpose, a previously used experimental facility on cooling cycle [Coskun S, Pulat E, Unlu K, Yamankaradeniz R. Experimental performance investigation of a horizontal ground source compression refrigeration machine. International journal of Energy Research 2008: 32: 44-56] was modified for the heating cycle. Soil thermal conductivity estimation was expanded and discussed. Preliminary numerical temperature distribution around GHE pipes was obtained. Tests were performed under laboratory conditions for space heating from December 2004 to March 2005. Variations of entering and leaving antifreeze solution temperatures, extracted heat from ground and rejected heat to the test room, super heat rate in evaporator and subcooling rate in condenser, total power consumption and coefficient of performance (COP) values for both the entire system and only heat pump unit (HPU) were obtained. Effect of outdoor temperature on system capacities and COP values with respect to outdoor air and mean soil temperatures were also presented. The COP of the entire system and HPU lie between 2.46-2.58 and 4.03-4.18, respectively. GSHP system was compared to conventional heating methods in the economical analysis and it was shown that the GSHP system is more cost effective than the all other conventional heating systems.Item Investigation of heat transfer types in an automobile fog lamp with computational fluid dynamic analysis(Znack Publishing House, 2016) Sökmen, Kemal Furkan; Coşkun, Salih; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu.; 0000-0001-8647-4861; R-5685-2016; GIO-5450-2022; CMA-0559-2022; 55959184900; 26645227400; 26644674500This study investigated the temperature distribution and heat transfer in an automobile fog lamp. First, a mesh independent solution was obtained. The results were compared with the literature and validated with test results. Measurements were taken from five different points by using thermocouple. Tests were applied for two hours at 24 degrees C. For thermal analysis, ANSYS CFX 12.1 was employed. Air flow inside the fog lamp was assumed as steady, incompressible, laminar and three-dimensional. Thermophysical property variations, buoyancy and radiation effects were taken into consideration. The radiation effect is an important heat transfer type to be considered in the temperature distribution on the lenses of automotive lighting systems. The radiation effect can have a negative influence on the lens due to the selection of unsuitable material. Despite the complexity of the bulb geometry and its non-isothermal surface conditions, general flow and heat transfer characteristics did not change.Item Investigation of parameters affecting organic rankine cycle efficiency by using Taguchi and ANOVA methods(Pergamon-Elsevier Science, 2018-12-25) Bademli̇oğlu, Ali Hüsnü; Canbolat, Ahmet Serhan; Yamankaradeniz, Nurettin; Kaynaklı, Ömer; Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; HPH-3328-2023; AAA-1753-2021; DBD-5807-2022; 57196950859; 26645227400; 8387145900There are many factors affecting the Organic Rankine Cycle's (ORC) performance, such as working fluid selection, evaporator and condenser temperatures, pinch point temperature differences (the minimum temperature difference between refrigerant and the waste heat source (PPTDevap) or cooling water (PPTDcon)), superheating temperature, heat exchanger effectiveness, and isentropic efficiencies of the turbine and pump. In this study, the parameters' impact weights on the cycle's efficiency are discussed and comparatively examined based on the statistical analyses. First, the system's thermodynamic model was established, and variation of the cycle's thermal efficiency was calculated for different parameters and their different ranges. Next, to obtain the contribution ratios and the order of importance of these parameters, the thermodynamic analysis results were evaluated using two statistical methods: Taguchi and ANOVA. In conclusion, the evaporator and condenser temperature and the turbine efficiency have a large effect on the thermal efficiency of the ORC, and the total impact ratio of these parameters is determined as approximately 70%. However, PFTDevap, PPTDcon and pump efficiency are found to be the least effective parameters. In addition, the best and the worst operating conditions are determined from the statistical analysis and in these operating conditions, the thermal efficiencies of the ORC are obtained as 18.1% and 9.6%, respectively.Item Investigation of the number of particles in an operating room at different ambient temperatures and inlet velocities(Taylor & Francis, 2017-10-11) Ufat, Hande; Kaynaklı, Ömer; Yamankaradeniz, Nurettin; Yamankaradeniz, Recep; Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü.; AAA-1753-2021; AAK-4166-2021; 8387145900; 57195235906; 26645227400; 6507733785This study presents some field measurements in an operating room of air velocity, ambient temperature and particle counts on the operating table. Moreover, computational fluid Dynamics analyses of the operating room were performed and compared with the measurements. Measurements were taken under the preferred operating conditions by surgical staff (at 19 degrees C) and then at different ambient temperatures (from 20 to 22 degrees C, varying by one-degree increments) and average inlet air velocities (V-j) (0.1 and 0.2 m/s). The preferred one by surgical staff is 0.1 m/s and the maximum that can be reached is 0.2 m/s, with the current system. The results show that the particle count decreased at V-j of 0.2 m/s and low temperatures.Item Isı merkezlerinde açığa çıkan atık ısı enerjisinin absorbsiyonlu soğutma çevrimi ile geri kazanımı(Bursa Uludağ Üniversitesi, 2023) Karabakal, Emre; Yamankaradeniz, Nurettin; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.; 0000-0003-4761-9786Bu tez çalışmasında Balıkesir ilinde bölgesel ısıtma sistemi ile ısıtma ihtiyacı karşılanan bir tesis ele alınmıştır. Tesisin ısı merkezinde bulunan buhar kazanlarında yanma işlemi sonucu açığa çıkan egzoz gazının ısı enerjisinden faydalanılmaktadır. Isı enerjisi kullanılarak LiBr-H2O ve H2O- NN3 eriyik çiftlerinin kullanıldığı, tek ve iki kademeli absorbsiyonlu soğutma sistemiyle soğutma yükü oluşturulacağı değerlendirilmektedir. LiBr-H2O ve H2O- NN3 çiftleri kullanılan absorbsiyonlu soğutma sistemleri için kütle ve enerji denklemleri incelenmektedir. Elde edilen denklemlerin EES (Engineering Equation Solver) programı yardımıyla termodinamik hesaplamaları yapılmaktadır. Tesisin baca gazı ısısındaki değişimlerin absorbsiyonlu soğutma sistemi üzerinde STK (Soğutma Tesir Katsayısı) etkisini görebilmek için farklı kaynatıcı sıcaklıkları alınarak STK hesaplamaları yapılmaktadır. Yoğuşturucu sıcaklıklarının STK üzerine etkisini incelemek amacıyla farklı yoğuşturucu sıcaklıkları alınarak STK değişimlerine bakılmaktadır. İhtiyaç duyulan sıcaklık değerlerinin STK üzerine etkisini incelemek üzere farklı buharlaştırıcı sıcaklıklarının STK üzerine etkisi incelenmektedir. Farklı absorber sıcaklıklarının STK üzerine etkisine bakılmaktadır. Absorbsiyonlu soğutma sisteminde kullanılan eşanjör etkinliğinin, STK üzerinde ki etkisinin görülmesi amacıyla farklı eşanjör etkinliklerinin sonucunda oluşan STK değerleri incelenmektedir. Farklı kaynatıcı sıcaklıkları sonucunda STK değerleri incelendiğinde, 60 ºC ile 180 ºC arasında kaynatıcı sıcaklıklarına karşılık gelen STK değerlerine bakılmıştır. Düşük sıcaklık değerlerinde tek kademeli, yüksek sıcaklık değerlerinde iki kademeli sistemlerin kullanılmasının STK değerini artıracağı gözlemlenmiştir. Yoğuşturucu sıcaklıklarına bakıldığında, tek kademeli sistemlerde düşük yoğuşturucu sıcaklıklarındaki düşüşler ile STK değerinin arttığı görülmüştür. Artan buharlaştırıcı sıcaklıkları ile STK değerinin arttığı sonucuna varılmıştır. Absorber sıcaklıklarına bakıldığında, tek kademeli sistemlerde artan absorber sıcaklığı ile STK değerinin düştüğü, iki kademeli sistemlerde birincil absorberde ki sıcaklık değişiminin STK değerini değiştirmediği sonucuna varılmıştır. Ayrıca eşanjör etkinliği incelendiğinde ise, eşanjör etkinlik değerinin artması sonucunda STK değerlerinin hızla yükseldiği görülmektedir.Item Isı pompası destekli kurutma sistemlerinde by-pass oranının kurutma performansına etkisinin deneysel analizi(Uludağ Üniversitesi, 2012-06-27) Yamankaradeniz, Nurettin; Coşkun, Salih; Pastakkaya, Bilsay; Can, Muhiddin; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksek Okulu/İklimlendirme Soğutma Programı.; Uludağ Üniversitesi/Orhangazi Meslek Yüksek Okulu/Makine Programı.; Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü.Bu çalışmada R134a soğutucu akışkan kullanılan prototip bir kapalı sistem ısı pompası destekli kurutucu deney düzeneği tasarlandı ve test edildi. İki farklı hız için by-pass oranının sistem performansına etkisi incelendi. Sistem performansına etki eden parametreler, ısı pompası ısıtma tesir katsayısı (ITKıp), tüm sistemin ısıtma tesir katsayısı (ITKsis) ve özgül nem çekme oranı (SMER) hesaplandı. Deneysel sonuçlarda, by-pass oranı % 50’den fazla olduğu durumlarda ITK ve SMER değerlerinin azaldığı görüldü. ITK ve SMER değerleri yaklaşık % 50 by-pass oranına kadar arttığı ve daha sonra hızla azaldığı görüldü. Maksimum ITKıp, ITKsis, SMER değerleri yaklaşık olarak 4.8, 3.2 ve 3.5 kg/kWh olarak elde edildi. Ayrıca hava debisinin arttırılmasının sistem performansını iyileştirmediği gözlemlendi. Çünkü yüksek hava debilerinde fanın tükettiği güç değeri de fazla olduğundan dolayı ITKsis değeri olumsuz yönde etkilendi.Item Jeotermal destekli absorbsiyonlu soğutma sisteminin termodinamik ve ekonomik analiz: Simav örneği(Türk Isı Bilimi Teknolojisi Bilimi, 2016-03-04) Tuğcu, Abtullah; Arslan, Oğuz; Köse, Ramazan; Yamankaradeniz, Nurettin; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/Elektrik-Enerji Bölümü.; AAA-1753-2021Bu çalışmada, jeotermal enerji destekli, NH3-H 20 eriyiği ile çalışan tek kademeli absorbsiyonlu soğutma sisteminin, farklı eriyik konsantrasyonları ve tasarım parametrelerine göre optimizasyonu yapılmıştır. Parametrik değerlendirme sonrasında 3660 farklı tasarım oluşturulmuş ve bu tasarımlar çerçevesinde sistem performanslarının; ısıtıcı, buharlaştıncı, yoğuşturucu ve absorber sıcaklıkları ile değişimi enerji ve ekserji analiz metotları kullanılarak incelenmiştir. Hesaplamalarda NH3-H 20 eriyiğinin karışım oranları % 46 NH3-% 54 FLO, % 40 NH3-% 60 H20 , % 30 NH3-% 70 H20 , % 20 NH3-% 80 H20 şeklinde dikkate alınmıştır. Çalışmanın ayrıca; Simav jeotermal kaynakları kullanılarak tasarlanan ve optimize edilen absorbsiyonlu soğutma sisteminin faydalı ömrü 20 yıl olarak dikkate alınmış olup, bölgede ve yakın çevresinde yetişen üzüm, elma ve ayva gibi ürünlerin soğuk muhafaza yöntemi ile saklanması planlanarak, sistemin optimizasyonu Net Bugünkü Değer (NBD) metoduyla yapılan ekonomik değerlendirme sonucu belirlenmiştir. Optimum sistem için, STK değeri 0,5722 ve ekserji verimi 0,6201 olarak hesap edilmiş, ürün grubunun ayva olması durumunda, sistemin NBD'si 3.912.757,74 TL, elma olması durumunda 13.922.203.39 TL ve üzüm olması durumunda ise 59.803.554.33 TL olarak hesap edilmiştir. Elde edilen bu sonuçlar dikkate alındığında, Simav jeotermal kaynaklarının kullanıldığı absorbsiyonlu bir soğutma sisteminin yatırıma uygun olduğunu tespit edilmiştir.Publication Led junction and heatsink number calculation with computational fluids dynamic (CFD)(Türk Isı Bilimleri Teknolojisi, 2015-01-01) Sökmen, K. Furkan; Pulat, Erhan; Yamankaradeniz, Nurettin; Coşkun, Salih; PULAT, ERHAN; YAMANKARADENİZ, NURETTİN; COŞKUN, SALİH; AAA-1753-2021; DLL-8342-2022; CMA-0559-2022A LED (Light Emmitting Diode) is an optoelectronic component which includes active layer among N and P type semiconductor products like a sandwich and electrical taps. Since 1995 LED is used in automotive sector. On this application, 0.5-0.75-1-1.25 W powered a typical car head light LED's junction temperature (T-j) rates with HAD resolutions at 25, 50, 80 degrees C and heat transmission rates are calculated. The winglet numbers and types, optimum winglet gaps were found out with macro according to evidences. The geometric model of LED was designed by CATIA V5 R19 software. It is divided into its components with ICEM CFD and its temperature analysis is done via ANSYS CFX 14. Its airflow is assumed as in constant regime, laminar and solid. Thermo physical features of the weather's changes related to heat, buoyancy and radiation effects are taken into consideration. Heat transmission rate on circuit and temperature rates are calculated and compared with the literature rates. Appropriate fin design developed with the help of program developed and despite the increasing ambient temperature, junction temperatures taken appropriate values. Optimum fin interval was found to be an important parameter in the design of heat sinks. LED should be located where the ambient temperature is low in headlamp for LED life and performance to be expected level.Item Mahallerin iklimlendirilmesinde kullanılan klima santrallerinde ısı geri kazanım yöntemleri ve dış hava ısısından faydalanmak(Bursa Uludağ Üniversitesi, 2019-09-05) Kota, Cantürk; Yamankaradeniz, Nurettin; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.; 0000-0003-0890-6694Yakın geçmişte ve günümüzde enerjiye sahip olmak için dünya ülkeleri birbirleriyle yarışmaktadır. Ülkemiz enerjiyi büyük oranda ithal etmektedir. Enerjinin ithali hem dış borçlanmayı arttırmakta hem de ülkemizin dışa bağımlılığını ortaya koymaktadır. Bu husus çerçevesinde dışa bağımlı olmak ülkemizin tam bağımsızlığı konusunda ciddi bir engeldir. Bu çalışma ile yatırımcı-akademi bir araya getirilmeye çalışılmıştır. Yatırımcının ürün bazlı satın almalarda ürün-ürün olarak değil ürün-genel sistem olarak bakması gerektiği gösterilmeye çalışılmıştır. Üç farklı duruma göre sistemler çalışılmıştır. Santral debileri uluslararası standartlara göre belirlenmiştir. Isı geri kazanım çıkış sıcaklıkları ve ısıtma-soğutma batarya kapasiteleri bulunmuştur. Basınç kayıpları hesaplanarak pompa, kazan, soğutma grubu, tesisat vb. gruplar projelendirilmiştir. Ayrı ayrı sistemlerin keşif özetleri çıkartılarak malzeme ve işçilik maliyetleri girilmiştir. Ürün bazlı olarak ısı geri kazanımlı klima santralleri daha maliyetli olmakla birlikte genel sistem üzerinde daha uygun kalmaktadır. Bununla birlikte işletme maliyetleri ısı geri kazanımlı sistemlerde yıllık olarak ciddi derecede fark etmektedir. Ayrıca klima santrallerine by-pass hücresi eklenerek dış hava ısısından faydalandıldığı takdirde ne kadar enerji tasarrufu yapılabileceği gösterilmiştir.Publication Minimization of thermal insulation thickness taking into account condensation on external walls(Sage, 2015-09-01) Yamankaradeniz, Nurettin; YAMANKARADENİZ, NURETTİN; Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu; AAA-1753-2021Condensation occurs in the inner layers of construction materials at whatever point the partial pressure of water vapor diffuses and reaches its saturation pressure. Condensation, also called sweating, damages materials, reduces thermal resistance, and by increasing the total heat transfer coefficient, results in unwanted events such as increased heat loss. This study applied minimization of thermal insulation thickness with consideration given to condensation in the external walls. The calculations of heat and mass transfers in the structure elements are expressed in a graphical form. While there was an increase in the required thermal insulation thickness subsequent to an increase in the internal environment's temperature, relative humidity, and the external environment's relative humidity, the required thickness decreased with an increase in the external environment's temperature. The amount of water vapor transferred varied with internal or external conditions and the thickness of the insulation. A change in the vapor diffusion resistance of the insulation material can increase the risk of condensation on the internal or external surfaces of the insulation.