Browsing by Author "Bademlioğlu, Ali Hüsnü"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Publication A parametric analysis of the performance of organic rankine cycle with heat recovery exchanger and its statistical evaluation(Turkish Soc Thermal Sciences Technology, 2019-01-01) Bademlioğlu, Ali Hüsnü; Canbolat, Ahmet Serhan; YAMANKARADENİZ, NURETTİN; CANBOLAT, AHMET SERHAN; Yamankaradeniz, Nurettin; Kaynaklı, Ömer; KAYNAKLI, ÖMER; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; AAA-1753-2021; HPH-3328-2023; AAI-8222-2021In this study, the performance of a case study of Organic Rankine Cycle with heat recovery exchanger using different fluids is analyzed. As the fluids worked in the cycle, the commonly used R134a, R236fa, R245fa, R600a, R717 and R718 are preferred. Cycle performances of the selected fluids are compared based on both the heat source's temperature that changes between 80 degrees C and 109 degrees C and the effectiveness of the heat exchanger. Furthermore, the contribution ratios and the order of importance of the parameters affecting the performance of the cycle are evaluated using the Taguchi statistical method. As a result, the effect of the waste-heat source temperature on the performance of the system is greater than the other parameters examined, and the contribution ratio of this parameter is determined as 59.80%. However, effectiveness of heat exchanger is found to be the least effective parameter and the effect ratio is calculated as 2.18%. In addition, the best and worst operating conditions are determined from the statistical analysis, and in these conditions, the thermal efficiencies of the Organic Rankine Cycle are obtained as 15.26% and 8.61%, respectively.Item Bina dış duvarlarında yoğuşma dikkate alınarak gerekli yalıtım kalınlığının belirlenmesi: Bitlis ili için örnek çalışma(Bursa Uludağ Üniversitesi, 2018-12-05) Bademlioğlu, Ali Hüsnü; Canbolat, Ahmet Serhat; Kaynaklı, Ömer; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.Türkiye gibi dış ortam sıcaklıklarının geniş bir aralıkta değişkenlik gösterdiği ülkelerdeki binalarda, kış aylarında ısı kayıplarını, yaz aylarında ise ısı kazançlarını azaltmak için yapılan yalıtım uygulamalarının önemi her geçen gün artmaktadır. Yapılan yalıtım uygulamalarında su buharı hareketlerinin göz önüne alınması yoğuşma riski açısından oldukça önemlidir. Yoğuşma veya terleme olarak adlandırılan bu olay, malzemelerin zarar görmesi, mukavemetin azalması ve toplam ısı transfer katsayısının yükselmesi nedeniyle ısı kayıplarının artması gibi istenmeyen sonuçlar doğurur. Bu çalışmada dıştan yalıtımlı duvar tipi seçilmiş ve Bitlis ili için yapılan yalıtım uygulamasında yoğuşma riski dikkate alınarak, aylara göre gerekli minimum yalıtım kalınlıkları hesaplanmıştır. Yoğuşma riskinin en fazla olduğu ve bu nedenle yoğuşmayı önlemek için gereken yalıtım kalınlığının maksimum olduğu ay olarak şubat ayı belirlenmiştir. Yapı elemanındaki ısı ve kütle transferi hesaplamaları, farklı iç ortam sıcaklıkları ve bağıl nem koşulları için yapılmıştır. Belirlenen çalışma şartlarında, şubat ayı için gerekli minimum yalıtım kalınlığı yaklaşık 0,104 m olarak hesaplanmıştır.Item Duvarlarda yoğuşma dikkate alınarak yalıtım kalınlığının belirlenmesi(Uludağ Üniversitesi, 2014) Bademlioğlu, Ali Hüsnü; Kaynaklı, Ömer; Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.Bu tez çalışmasında yoğuşma dikkate alınarak bina dış duvarlarında kullanılacak ısıl yalıtım kalınlığının optimizasyonu yapılmıştır. Bina yapı elemanı içerisinde yoğuşmanın başlamaması için gerekli minimum yalıtım kalınlığı belirlenmiştir. Yapı elemanında ısı ve kütle transferi hesaplamaları, farklı iç-dış ortam sıcaklığı ve bağıl nem koşulları için yapılmış ve sonuçlar grafik yardımıyla aktarılmıştır. Genel olarak, gerekli yalıtım kalınlığı iç ortam sıcaklığı ve bağıl neminin artmasıyla artarken, dış ortam sıcaklık ve bağıl neminin artmasıyla azalmaktadır. Duvar yapı malzemesinden geçen su buharı miktarı ise iç ve dış koşulların yanı sıra kullanılan yalıtım kalınlığıyla da değişmektedir.Item Exergy analysis of the organic rankine cycle based on the pinch point temperature difference(Yıldız Teknik Üniversitesi, 2019-04) Bademlioğlu, Ali Hüsnü; Yamankaradeniz, Recep; Kaynaklı, Ömer; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makina Mühendisliği/Termodinamik Bölümü.; Yurtiçi; 6507733785; 8387145900Organic Rankine Cycle (ORC) is a system that uses working fluids with hydrocarbon components instead of water and generates power from the heat recovery of different heat sources. In this study, the exergy analysis of a simple ORC, which produces electrical energy with the help a geothermal source (125 degrees C), was performed. R123, R152a, R245fa and R600a were determined as the fluids to be used in the Cycle. In this analysis, which was carried out according to the pinch point temperature differences (5-20 degrees C) in the evaporator, the exergy performance of the cycle components was evaluated for the geothermal resource unit flow rate and the variation of the exergy efficiency of the system was calculated. With the increase of the pinch point temperature difference in the evaporator, the decrease of the system's exergy efficiency became maximal (11.7%) with the use of R152a as a refrigerant and the loss in the system's exergy efficiency became minimal (9.03%) with the use of R123 as a refrigerant.Item Investigation of parameters affecting the optimum thermal insulation thickness for buildings in hot and cold climates(Vinca Institute of Nuclear Science, 2020) Bademlioğlu, Ali Hüsnü; Canpolat, Ahmet Serhan; Kenan, Saka; Kaynaklı, Ömer; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; Bursa Uludağ Üniversitesi/Yenişehir Meslek Yüksekokulu/İklimlendirme ve Soğutma Bölümü.; 0000-0002-2296-894X; 0000-0002-0423-6411; AAI-8222-2021; AAH-5303-2021; 57196950859; 56865845300; 8387145900This paper investigates the factors affecting the optimum insulation thickness and its pay-back period, such as heating and cooling energy requirements of building, lifetime, present worth factor, costs of insulation material and installation, costs of energy sources for heating and cooling, heating and cooling system efficiencies, and solar radiation. For this purpose, by considering two cities characterizing the hot and cold climatic conditions, the optimum insulation thickness and its payback period have been calculated and a detailed parametric analysis has been carried out. To achieve practical results, the ranges of the parameters considered in the study include the values typically reported in the literature. The variations in the optimum insulation thickness and the pay-back period with all parameters are presented in graphical form. Finally, order of importance and contribution ratios of the examined parameters on the optimum insulation thickness are determined with the help of Taguchi method. It is found that heating degree-days is the most efficient parameter on the optimum insulation thickness with an impact ratio of 27.33% of the total effect while the least efficient parameter is the efficiency of heating system with an impact ratio of 3.21%.Item Jeotermal enerji kullanılarak sıvı hidrojen üretimi için geliştirilen ORC destekli çok fonksiyonlu bir sistemin modellenmesi, termodinamik optimizasyonu ve eksergoekonomik analizi(Bursa Uludağ Üniversitesi, 2020-12-31) Bademlioğlu, Ali Hüsnü; Kaynaklı, Ömer; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.; 0000-0001-6944-4900Bu çalışmada, sıvı hidrojen üretimi için geliştirilen jeotermal enerji kaynaklı ve alt modül olarak sırasıyla ORC sistemi, yüksek sıcaklıklı elektroliz, absorbsiyonlu soğutma ve hidrojen sıvılaştırma çevrimlerinden oluşan kapsamlı, çok fonksiyonlu bir sistem modellenmiş, modellenen sistemin termodinamik optimizasyonu ve eksergoekonomik analizleri gerçekleştirilmiştir. Sıvı hidrojen üretimi için modellenen sistemin termodinamik performansı ORC sistemlerinde kullanılan farklı soğutucu akışkanlar (R123, R245fa, R601, n-Hexane) için farklı buharlaştırıcı sıcaklıklarında (100⁰C-150⁰C) incelenmiştir. Ayrıca çalışma kapsamında farklı sıvılaştırma çevrimleri ve absorbsiyonlu soğutma sisteminde kullanılan eriyik çiftleri dikkate alınarak hidrojen üretim sistemi için altı farklı model oluşturulmuştur. Modellerin enerji ve ekserji analizleri gerçekleştirilmiş, sıvı hidrojen üretim performansları karşılaştırılmış ve sistem için optimum çalışma parametreleri belirlenmiştir. Optimum çalışma şartları için eksergoekonomik analizler gerçekleştirilmiş ve sistemi oluşturan komponentlerin eksergoekonomik performansları değerlendirilmiştir. Oluşturulan tüm modeller birlikte ele alındığında, ön soğutmalı Claude sıvılaştırma sisteminin kullanıldığı ve absorbsiyonlu soğutma çevriminde NH3-H2O eriyik çiftinin tercih edildiği Model 2’nin termodinamik performansının diğer modellere kıyasla daha yüksek olduğu ve hidrojen üretim miktarı açısından ise daha kullanılabilir olduğu belirlenmiştir. Sabit çalışma şartlarında, soğutucu akışkan ve buharlaştırıcı sıcaklığına bağlı olarak Model 2’de üretilen hidrojen miktarı maksimum 0,18049 kg/s olarak hesaplanmış, enerji ve ekserji verimi ise sırasıyla maksimum %11,56 ve %35,09 olarak belirlenmiştir. 150⁰C buharlaştırıcı sıcaklığı ve n-Hexane için Model 2’nin eksergoekonomik analizleri gerçekleştirilmiş ve elektroliz ünitesi 441,206 USD/h ile en yüksek yatırım maliyetine sahip komponent olmuştur. Ayrıca sistemde, ekserji yıkım maliyeti en yüksek olan komponentin 61,206 USD/h maliyet ile Claude sıvılaştırma sistemindeki (2) numaralı eşanjör olduğu belirlenmiştir. Sıvılaştırılan hidrojenin birim ekserji maliyeti 11,277 USD/GJ olarak hesaplanmıştır.Item Performance assessments of organic rankine cycle with internal heat exchanger based on exergetic approach(American Society of Mechanical Engineers (ASME), 2018-10) Bademlioğlu, Ali Hüsnü; Yamankaradeniz, Nurettin; Kaynaklı, Ömer; Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; AAA-1753-2021; DBD-5807-2022; 26645227400; 8387145900This study makes energy and exergy analysis of a sample organic Rankine cycle (ORC) with a heat exchanger which produces energy via a geothermal source with a temperature of 140 degrees C. R600a is preferred as refrigerant to be used in the cycle. The changes in exergy destructions (of irreversibility) and exergy efficiencies in each cycle element are calculated in the analyses made based on the effectiveness of heat exchanger used in cycle and evaporator temperature changing between 60 and 120 degrees C for fixed pinch point temperature differences in evaporator and condenser. Parameters showing system performance are assessed via second law approach. Effectiveness of heat exchanger and temperature of evaporator are taken into consideration within the scope of this study, and energy and exergy efficiencies of cycle are enhanced maximum 6.87% and 6.21% respectively. Similarly, exergy efficiencies of evaporator, heat exchanger, and condenser are increased 4%, 82%, and 1.57%, respectively, depending on the effectiveness of heat exchanger and temperature of evaporator.Publication Thermohydraulic performance optimization of automobile radiators using statistical approaches(Asme, 2022-05-01) Canbolat, Ahmet Serhan; Bademlioğlu, Ali Hüsnü; Kaynaklı, Ömer; CANBOLAT, AHMET SERHAN; KAYNAKLI, ÖMER; Bursa Uludağ Üniversitesi/Gemlik Asım Kocabıyık Meslek Yüksekokulu/Hibrit ve Elektrikli Araç Teknolojisi Programı.; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; HPH-3328-2023; DBD-5807-2022Automobile radiator which is one of the vital components used for engine cooling in vehicles is expected to provide higher thermal performance without changing the exterior dimensions of the radiator with the development of engine technology. This situation necessitates changes in both design and operating parameters in the currently used radiator. In the present study, all fundamental parameters affecting the thermal and hydraulic performance of an automobile radiator are evaluated and optimized with statistical methods. Optimization study is carried out using Taguchi and ANOVA methods for two specified objective functions (heat transfer and pressure drop). The order of importance and impact rates for each design and operating parameter, the best and worst working conditions in terms of both target functions are determined. Air velocity, air inlet temperature, coolant inlet temperature, and fin pitch are found to be the most effective parameters on the heat transfer with a contribution ratio of 88%. The best and worst working conditions are obtained for the heat transfer and under these working conditions, they are calculated as 43.68 kW and 1.63 kW, respectively. When the system is examined in terms of the pressure drop, the results show that the coolant flowrate and tube height have a great impact with a contribution ratio of 67.04% and 32.06%, respectively. Lastly, the maximum and minimum pressure drop within the studied operating condition range is determined as 20.68 kPa and 0.12 kPa, respectively.