Publication:
Net analyte signal-based simultaneous determination of dyes in environmental samples using moving window partial least squares regression with UV-vis spectroscopy

dc.contributor.buuauthorŞahin, Saliha
dc.contributor.buuauthorSarıburun, Esra
dc.contributor.buuauthorDemir, Ceren
dc.contributor.departmentFen Edebiyat Fakültesi
dc.contributor.departmentKimya Ana Bilim Dalı
dc.contributor.orcid0000-0003-1508-0181
dc.contributor.orcid0000-0002-9381-0410
dc.contributor.orcid0000-0002-4101-8448
dc.contributor.researcheridAAH-2892-2021
dc.contributor.researcheridABA-2005-2020
dc.contributor.scopusid15027401600
dc.contributor.scopusid33867732000
dc.contributor.scopusid7003565902
dc.date.accessioned2022-01-11T07:01:36Z
dc.date.available2022-01-11T07:01:36Z
dc.date.issued2009-12
dc.description.abstractThe multivariate calibration methods-moving window selection partial least squares regression (MWPLSR) and net analyte signal (NAS)-were employed for simultaneous determination of a mixture of C.I. Disperse Blue 183, C.I. Disperse Blue 79. C.I. Disperse Red 82, C.I. Disperse Red 65, C.I. Disperse Yellow 211 and C.I. Disperse Orange 25 by UV-vis spectrophotometry. The absorption spectra of the six disperse dyes were recorded between 320 and 680 nm. A modified changeable size moving window partial least squares (CSMWPLS) and searching combination moving window partial least squares (SCM WPLS) were proposed to search for an optimized spectral interval and an optimized combination of spectral regions from informative regions obtained by MWPLSR. Different wavelength regions were selected by taking into account different spectral parameters including the starting wavelength, the ending wavelength and wavelength interval. It was found that wavelength selection improved the performance of the corresponding net analyte signal-partial least squares (NAS-PLS) model, in terms of root mean square error (RMSE), compared with the results obtained using whole spectra or direct combination of informative regions for each dye. The importance of calibration design was also investigated by calculating the prediction and validation errors. The influence of using independent validation sets were emphasized. The proposed calibration method gave better results in combination and informative spectral regions for determination of the six disperse dyes without prior separation.
dc.identifier.citationŞahin, S. vd. (2009). "Net analyte signal-based simultaneous determination of dyes in environmental samples using moving window partial least squares regression with UV-vis spectroscopy". Analytical Methods, 1(3), 208-214.
dc.identifier.endpage214
dc.identifier.issn1759-9660
dc.identifier.issue3
dc.identifier.pubmed32938060
dc.identifier.scopus2-s2.0-77953653692
dc.identifier.startpage208
dc.identifier.urihttps://doi.org/10.1039/b9ay00009g
dc.identifier.urihttps://pubs.rsc.org/en/content/articlelanding/2009/AY/b9ay00009g
dc.identifier.urihttp://hdl.handle.net/11452/23985
dc.identifier.volume1
dc.identifier.wos000275164800008
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherRoyal Soc Chemistry
dc.relation.journalAnalytical Methods
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCalibration
dc.subjectUltraviolet spectroscopy
dc.subjectCalibration method
dc.subjectDisperse blue 79
dc.subjectDisperse dyes
dc.subjectDisperse red
dc.subjectEnvironmental sample
dc.subjectMoving window
dc.subjectMultivariate calibration methods
dc.subjectNet analyte signals
dc.subjectPartial least squares
dc.subjectPartial least squares regression
dc.subjectRoot mean square errors
dc.subjectSimultaneous determinations
dc.subjectSpectral parameters
dc.subjectSpectral region
dc.subjectUV-vis spectrophotometry
dc.subjectUV-vis spectroscopy
dc.subjectValidation errors
dc.subjectValidation sets
dc.subjectWavelength regions
dc.subjectWavelength selection
dc.subjectNear-infrared spectroscopy
dc.subjectMultivariate calibration
dc.subjectSpectrophotometric determination
dc.subjectAzo-dye
dc.subjectLiquid-chromatography
dc.subjectMass-spectrometry
dc.subjectWavelength range
dc.subjectSpectral regions
dc.subjectHuman serum
dc.subjectSelection
dc.subjectChemistry
dc.subjectFood science & technology
dc.subjectSpectroscopy
dc.subject.scopusMultivariate Calibration; Wavelength Selection; Mean Square Error of Prediction
dc.subject.wosChemistry, analytical
dc.subject.wosFood science & technology
dc.subject.wosSpectroscopy
dc.titleNet analyte signal-based simultaneous determination of dyes in environmental samples using moving window partial least squares regression with UV-vis spectroscopy
dc.typeArticle
dc.wos.quartileQ2
dc.wos.quartileQ3
dspace.entity.typePublication
local.contributor.departmentFen Edebiyat Fakültesi/Kimya Ana Bilim Dalı
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: