Akay, CemalÖzkan, Sibel A.Şentürk, Zühre2021-07-052021-07-052002-11Akay, C. vd. (2002). "Simultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms by RP-HPLC". Farmaco, 57(11), 953-957.0014-827Xhttps://doi.org/10.1016/S0014-827X(02)01296-Xhttps://www.sciencedirect.com/science/article/pii/S0014827X0201296Xhttp://hdl.handle.net/11452/21035A reversed-phase high performance liquid chromatography (RP-HPLC) method with UV detection is described for the simultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms. Chromatography was carried out on a Cl 8 reversed-phase column, using a mixture of methanol-water (40 + 60, v/v) as a mobile phase, at a flow rate of 1.0 ml min(-1). Sulfamethoxazole was used as an internal standard and detection was performed using a diode array detector at 254 nm. The method produced linear responses in the concentration ranges 10-70 and 1-20 mug ml(-1) with detection limits 0.33 and 0.27 mug ml(-1) for metronidazole and micanozole, respectively. This procedure was found to be convenient and reproducible for analysis of these drugs in ovule dosage forms. (C) 2002 Editions scientifiques et medicales Elsevier SAS. All rights reserved.eninfo:eu-repo/semantics/closedAccessPharmaceutical dosage formsPharmacology & pharmacyReversed-phase high performance liquid chromatographyAmperometric detectionMetronidazole and miconazolePerformance liquid-chromatographyDerivatıve spectrophotometryCreamsPlasmaMetabolitesExtractionNitrateDrugsSimultaneous determination of metronidazole and miconazole in pharmaceutical dosage forms by RP-HPLCArticle0001804758000122-s2.0-0037210233953957571112484545Pharmacology & pharmacy