Gücü, ArifEriş, CüneytToktaş, FarukGöncü, TuǧrulÖzyazıcıoğlu, Ahmet Fatih2022-10-142022-10-142013-01-22Gücü, A. vd. (2013). "Effects of temporary vascular occluder poloxamer 407 Gel on the endothelium". Journal of Cardiothoracic Surgery, 8(1).1749-8090https://doi.org/10.1186/1749-8090-8-16https://cardiothoracicsurgery.biomedcentral.com/articles/10.1186/1749-8090-8-16http://hdl.handle.net/11452/29100Background: Coronary occlusion techniques during OPCAB may lead to an endothelial damage to the target vessel. The adverse effects of these techniques are well-known, and researches have been trying to find out new materials to occlude the coronary artery without an endothelial damage. In the present study, we investigate to the endothelial damage in the rat aorta which is occluded by Poloxamer 407 gel. Methods: Forty-five rats were randomized in three groups: (1) segment of the aorta was occluded with Poloxamer 407 gel in P 407 group; (2) segment of the aorta was occluded with microvascular clamp in MV clamp group; and (3) no onclusion was available in the Control group. The rats were sacrificed of observation, and a 15mm segment of the aorta was obtained as a specimen. Integrity of the endothelial lining was observed with a scanning electron microscopy. Results: Scanning electron microscopy revealed a statistically significant difference among the 3 groups (p<0,001) using the SPSS 13.0 test. No difference was found between the Control group and the P 407 group (p=0,059). The differences between MV clamp-Control group (p<0,001) and MV clamp-P 407 group were statistically significant (p<0,002). Conclusions: We suggest that Poloxamer 407 gel occlusion may be a safer and more effective method compared to the microvascular clamp occlusion.eninfo:eu-repo/semantics/openAccessCardiovascular system & cardiologySurgeryEndothelial damagePoloxamer 407Scanning electron microscopyOPCABCoronary-artery occlusionIntracoronary shunDysfunctionInjuryDamageAnimalsAortaCoronary occlusionEndothelium, vascularFemaleHemostatic techniquesMicroscopy, electron, scanningPoloxamerRatsRats, wistarStatistics, nonparametricEffects of temporary vascular occluder poloxamer 407 Gel on the endotheliumArticle0003152852000012-s2.0-848724313748123339359Cardiac & cardiovascular systemsSurgeryClamps; Constrictions; Common Carotid ArteryPoloxamerAnimalAortaArticleCanimalDrug effectFemaleHeart infarctionHemostasisNemostasisPathologyRatScanning electron microscopyVascular endotheliumWistar rat