Comparison of IgG and semiquantitative tests for evaluation of passive transfer immunity in calves

dc.contributor.buuauthorTopal, Onur
dc.contributor.buuauthorBatmaz, Hasan
dc.contributor.buuauthorMecitoğlu, Zafer
dc.contributor.buuauthorUzbacı, Ender
dc.contributor.departmentUludağ Üniversitesi/Veteriner Fakültesi/İç Hastalıkları Anabilim Dalı.tr_TR
dc.contributor.departmentUludağ Üniversitesi/Veteriner Fakültesi/Biyoistatistik Anabilim Dalı.tr_TR
dc.contributor.orcid0000-0002-1933-7354tr_TR
dc.contributor.orcid0000-0003-1991-8957tr_TR
dc.contributor.orcid0000-0002-5557-121Xtr_TR
dc.contributor.orcid0000-0002-9634-0055tr_TR
dc.contributor.researcheridS-8278-2017tr_TR
dc.contributor.researcheridAAH-1712-2021tr_TR
dc.contributor.researcheridAAH-1677-2021tr_TR
dc.contributor.scopusid56548777100tr_TR
dc.contributor.scopusid6602783183tr_TR
dc.contributor.scopusid36457647300tr_TR
dc.contributor.scopusid55347697800tr_TR
dc.date.accessioned2024-01-24T11:11:39Z
dc.date.available2024-01-24T11:11:39Z
dc.date.issued2018-04-22
dc.description.abstractSerum immunoglobulin (IgG) and semiquantitative tests are used for the evaluation of passive transfer immunity (PTI) in calves. We aimed to evaluate PTI in calves by using a Brix refractometer, total protein (TP), gamma-glutamyl transferase (GGT), and glutaraldehyde coagulation test (GCT) on days 1, 3, and 7 after birth; to compare the results with serum IgG; and to evaluate which day these tests are given on will give the best results. The blood samples were collected from 60 Holstein dairy calves on day 0, just after birth, and on the 1st, 3rd, and 7th days after birth. The serum IgG concentration was measured by ELISA, the Brix % and TP concentrations with refractometers, and GGT activity using a dry chemistry system. The duration of the GCT was determined in the first 60 min. The IgG, TP concentration, and Brix % all peaked on the 3rd day of the study. GGT showed a significant decline after 24 h. Evaluating the Brix %, IgG, TP, and GCT levels more than 24 h after birth gives better results. However, GGT activity was observed as an early indicator of failure of passive transfer, as the GGT levels were highest 24 h after birth.en_US
dc.identifier.citationTopal, O. vd. (2018). ''Comparison of IgG and semiquantitative tests for evaluation of passive transfer immunity in calves''. Turkish Journal of Veterinary and Animal Sciences, 42(4), 302-309.en_US
dc.identifier.doihttps://doi.org/10.3906/vet-1712-43en_US
dc.identifier.endpage309tr_TR
dc.identifier.issn1300-0128
dc.identifier.issue4tr_TR
dc.identifier.scopus2-s2.0-85051629100tr_TR
dc.identifier.startpage302tr_TR
dc.identifier.urihttps://journals.tubitak.gov.tr/veterinary/vol42/iss4/11/en_US
dc.identifier.urihttps://hdl.handle.net/11452/39296en_US
dc.identifier.volume42tr_TR
dc.identifier.wos000447159000011tr_TR
dc.indexed.pubmedPubMeden_US
dc.indexed.wosSCIEen_US
dc.language.isoenen_US
dc.publisherBilimsel ve Teknolojik Araştırma Kurumutr_TR
dc.relation.bapKUAP (V)-2015/9tr_TR
dc.relation.journalTurkish Journal of Veterinary and Animal Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectVeterinary sciencesen_US
dc.subjectCalfen_US
dc.subjectImmunityen_US
dc.subjectBrix refractometeren_US
dc.subjectTotal proteinen_US
dc.subjectGamma-glutamyl transferaseen_US
dc.subjectGlutaraldehyde coagulation testen_US
dc.subjectGlutaraldehyde coagulation testen_US
dc.subjectDairy calvesen_US
dc.subjectBrix refractometeren_US
dc.subjectColostrum qualityen_US
dc.subjectProtein-concentrationen_US
dc.subjectBovine colostrumen_US
dc.subjectBeef-calvesen_US
dc.subjectSerumen_US
dc.subjectFailureen_US
dc.subjectImmunoglobulin-g concentrationen_US
dc.subject.emtreeGamma glutamyltransferaseen_US
dc.subject.emtreeGlutaraldehydeen_US
dc.subject.emtreeImmunoglobulin Gen_US
dc.subject.emtreeProteinen_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeBlood clotting testen_US
dc.subject.emtreeCalf (bovine)en_US
dc.subject.emtreeColostrumen_US
dc.subject.emtreeControlled studyen_US
dc.subject.emtreeEnzyme activityen_US
dc.subject.emtreeEnzyme linked immunosorbent assayen_US
dc.subject.emtreeFemaleen_US
dc.subject.emtreeHolstein cattleen_US
dc.subject.emtreeImmunityen_US
dc.subject.emtreeImmunoglobulin blood levelen_US
dc.subject.emtreeMaleen_US
dc.subject.emtreeMeasurement accuracyen_US
dc.subject.emtreeNonhumanen_US
dc.subject.emtreePassive immunizationen_US
dc.subject.emtreePredictive valueen_US
dc.subject.emtreeProtein expressionen_US
dc.subject.emtreeQuantitative analysisen_US
dc.subject.emtreeReceiver operating characteristicen_US
dc.subject.emtreeSensitivity and specificityen_US
dc.subject.emtreeVaccine failureen_US
dc.subject.scopusColostrum; Animals; Passive Immunizationen_US
dc.subject.wosVeterinary sciencesen_US
dc.titleComparison of IgG and semiquantitative tests for evaluation of passive transfer immunity in calvesen_US
dc.typeArticleen_US
dc.wos.quartileQ3 (Veterinary sciences)en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Topal_vd_2018.pdf
Size:
1.29 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections